7
715 589 04 21 00
Supplement, gauge
Gauge
Screwdriver 5 mm
116 589 02 07 00
715 589 08 21 00
W26.60-1140-12
Checking
1 Install guide (5.2) onto gauge (5.1).
2 Mount shift mechanism (4) with sleeve addition gauge (5.3) onto gauge (5.1) and secure firmly in place using 2 screws.
The notch lever (1) and shift finger (6) must be at the same level.
3 Install bridge addition gauge (5.4) onto gauge (5.1).
4 Check setting of shift finger (6) using feeler gauge.
The gap (arrows) must be the same on both sides.
Adjust
When the shift finger (6) is adjusted, the index bolt (7) must abut the notched element and at the same time be in the neutral position.
5 Warm notch lever (1) in area around grub screws (2) and remove using screwdriver (3).
6 Screw in new grub screws (2) until gap at shift finger (6) is equal on both sides (arrows).
Once the microencapsulation has cured do not twist the grub screws (2) anymore otherwise the locking of the grub screws (2) is no longer guaranteed.