Shift mechanism
Number | Designation | Trans-mission 714.120 | Trans-mission 714.140/ | Trans-mission | Trans-mission | |
BA26.60-N-1002-01E | Grub screw in notch lever | Nm | 25 | 25 | 35 | 35 |
714 589 02 21 00
Setting gauge
Torque wrench
001 589 67 21 00
T26.60-0056-11
1 Install shift mechanism (1) on the gauge.
The index bolt (3) must abut the notched element (4) and simultaneously be in neutral.
Checking
2 Using a feeler gauge measure the gap (arrows) on the right and left of the shift finger (5).
The gap (arrows) must be the same on both sides.
Adjust
3 Heat up the grub screws (2) with the hot air gun and remove.
4 Screw in the new grub screws (2) until the gap (arrows) at the shift finger (5) is the same on both sides.
Observe torque of grub screws (2).
Once the microencapsulation has cured do not twist the grub screws (2) any more otherwise the locking device of the grub screws is no longer guaranteed (2).