AR14.40-W-2024C | Remove/install magnetic adapter at filler neck of AdBlue tank | 23.11.10 |
ENGINES 900.9 in MODEL 375.1, 970, 972, 975, 976 with CODE (MS4) BlueTec 4
ENGINES 900.9 in MODEL 375.1, 970, 972, 975, 976 with CODE (MS5) BlueTec 5
ENGINES 902.9 in MODEL 375.3, 950.5 /6, 952.5 /6, 953.6, 954.5, 957 with CODE (MS4) BlueTec 4
ENGINES 902.9 in MODEL 375.3, 950.5 /6, 952.5 /6, 953.6, 954.5, 957 with CODE (MS5) BlueTec 5
ENGINES 902.9 in MODEL 375.1, 970, 972, 974, 975, 976 with CODE (MS4) BlueTec 4
ENGINES 902.9 in MODEL 375.1, 970, 972, 974, 975, 976 with CODE (MS5) BlueTec 5
ENGINES 924.9 in MODEL 958.0, 970, 972, 974, 975, 976 with CODE (MS4) BlueTec 4
ENGINES 924.9 in MODEL 958.0, 970, 972, 974, 975, 976 with CODE (MS5) BlueTec 5
ENGINES 925.9 in MODEL 970, 972, 974 with CODE (MS4) BlueTec 4
ENGINES 925.9 in MODEL 970, 972, 974 with CODE (MS5) BlueTec 5
ENGINES 926.9 in MODEL 950.5 /6, 952.5 /6, 953.6, 954.5, 957, 958.2 with CODE (MS4) BlueTec 4
ENGINES 926.9 in MODEL 950.5 /6, 952.5 /6, 953.6, 954.5, 957, 958.2 with CODE (MS5) BlueTec 5
ENGINES 926.9 in MODEL 958.0 with CODE (MS4) BlueTec 4
ENGINES 926.9 in MODEL 958.0 with CODE (MS5) BlueTec 5
W14.40-1175-08
1 Holes
2 Fastening hook
3 Tank cap
6 AdBlue tank
7 Magnetic adapter (Elafix 40)
4 Screwdriver
5 Assembly aid
| Removing | ||
Danger! | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Only pour AdBlue suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
| Notes on use, material properties and handling of AdBlue® | ||
1 | Unscrew tank cap (3) on AdBlue tank (6) | ||
2 | Introduce assembly aid (5) into bores (1) | ||
| Assembly aid for remove/install of magnetic adapter at AdBlue tank filler neck | ||
3 | Push fastening hooks (2) in direction of arrow inwards using two screwdrivers (4) and push in assembly aid (5) all the way | ||
4 | Pull out magnetic adapter (7) | ||
| Install | ||
5 | Press fastening hook (2) together by hand and introduce assembly aid (5) all the way into bores (1) | ||
| Assembly aid for remove/install of magnetic adapter at AdBlue tank filler neck | ||
6 | Introduce magnetic adapter (7) all the way into AdBlue tank (6) filler neck | ||
7 | Hold magnetic adapter (7) firmly and pull out assembly aid (5) | While pulling out the assembly aid (5) the fastening hooks (2) snap in audibly. |