Pump module connection end |
1 | Connection contact (Ø 1.5 mm ELA) |
2 | Seal |
3 | Cable (white) |
4 | Cable (white/black) |
5 | Corrugated hose insulation |
6 | Plug |
7 | Contact socket |
W14.40-1291-04
Connection end to the SCR chassis control unit outlet |
3 | Cable (white) |
4 | Cable (white/black) |
5 | Corrugated hose insulation |
8 | Seal |
9 | Connection contact (MCP 1.5 ELA) |
W14.40-1289-01
1 | Turn off ignition | ||
2 | Insert the electrical cables (3,4) into the corrugated hose insulation (5) | The new harness with the cables (3,4) should not be the one integrated in the SCR harness insulation between the pump module and the chassis control unit, it must be arranged next to it. | |
3 | Install the connector on the cables (3,4) on the pump module contact |
| |
Crimp the electrical fitting contacts (1) with crimping pliers. | |||
4 | Install the electrical cables (3,4) into the fitting contact (9) of the SCR chassis control unit connection |
| |
Crimp the electrical fitting contacts (9) with crimping pliers. |