B14.40-0119-07
1 | Connectors locking pawl | 3 | Electric connector of level sensor | |
2 | Connectors | 4 | Level sensor |
| Remove/install | ||
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Notes on use, material properties and handling of AdBlue® | . | ||
1 | Turn off ignition | ||
2 | Draining the AdBlue from reservoir | Do not reuse drained AdBlue, because it may be contaminated and thus cause damage to the system. | |
3 | Remove the fastening strap from the AdBlue reservoir | ||
4 | Turn down the AdBlue reservoir just enough to gain access to the level sensor (4) | Be careful not to damage the AdBlue tubing and the level sensor wiring harness. | |
5 | Open the connector lock (1) | Press the two ends of the connectors lock (1), one against the other as indicated by the arrow, until he realized that the connectors (2) are free to be removed. | |
6 | Remove the connectors (2) | ||
7 | Stanch the AdBlue lines with clips to prevent leakage | Clamp | |
8 | Remove the electric connector from level sensor (3) | Turn the level sensor electric connector (3) counterclockwise until it is automatically released from the level sensor (4). | |
9 | Remove the level sensor (4) | Installation: Turn the level sensor (4) counterclockwise, as indicated by the arrow. | |
Installation: Pay attention that the sealing ring be correctly positioned between the level sensor (4) and the AdBlue reservoir. | |||
10 | Install on the reverse order |
000 589 54 37 00
Clamp