1 | Exhaust gas recirculation cooler |
4 | Left charge air distributor |
6 | Bolts |
7 | Bolts |
S14.20-4569-75
Warning | Risk of burn injuries, suffocation and poisoning when working on the exhaust system and the components connected to it. Risk of suffocation and risk of poisoning caused by inhalation of gaseous and solid components of the exhaust. Risk of poisoning caused by skin contact with solid components of the exhaust. | Wear protective clothing and safety glasses. Use the extraction system. Move people out of the hazard area. | |
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Remove the charge air distributors. | ||
2 | Unscrew the screws (6, 7) on the left charge air distributor (4). | Pay attention to different lengths of screws. | |
Bolt, exhaust gas recirculation cooler to charge air distributor | |||
3 | Remove the exhaust gas recirculation cooler (1). | Installation: Replace seals. | |
4 | Install in the reverse order |