1 | Transmission |
2 | Coupling housing |
3 | Bolts |
4 | Electrical connector |
5 | Coupling pressure line |
6 | Clip |
M32 | Hybrid system electric motor |
W08.10-1002-06
| Remove/install | ||
Warning | Risk of injury to hands or eyes when working on hydraulic pressure reservoir systems caused by hydraulic fluid to specification 345.0 spraying out under pressure | Depressurize hydraulic pressure reservoir system before commencing work on system. Wear protective gloves and safety glasses. | |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | Notes on self-locking nuts and bolts | ||
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
1 | Remove hybrid system electric motor (M32) with transmission | ||
2 | Disconnect electrical connection (4) | ||
3 | Take off clamp (6) | ||
4 | Unclip fuse and remove coupling pressure line (5) | Installation: Replace fuse . | |
5 | Unscrew bolts (3) around circumference of hybrid system electric motor (M32) | Bolt, electric motor to transmission | |
Torque wrench | |||
Insertion tool | |||
6 | Remove transmission (1) from hybrid system electric motor (M32) | Coupling housing (2) must no be removed from hybrid system electric motor (M32). | |
7 | Install in the reverse order |
001 589 66 21 00
Torque wrench
112 589 01 03 00