AR07.15-G-3000DE | Change data record, software, parameters in engine control (MR) control unit | 20.6.11 |
ENGINES 900.92, 902.93, 924.93, 926.95 /97, 541.95 in MODEL 000.001
with BlueTec®,
parameterization with MiniDiag
Parameterize | |||
1 | Connect MiniDiag | Observe operator's manual for MiniDiag. | |
2 | Switch on ignition | During parameterization, do not Perform on-board diagnosis, Run or start the engine and the battery for power supply must not be clamped off. | |
3 | Select "Automatic control unit recognition" | ||
4 | Select "KWP2000: IES/J1939" | ||
5 | Select "MR" | ||
6 | Select "Parameterization" | ||
7 | Select "Read or alter parameter from control unit " | ||
8 | Select "Proportional valves (PV)" | ||
9 | Select Proportional valve "PV1" | ||
10 | Switch actuation for "diffuser heater" on or off | To activate: actuate button "4" and then "OK" on the operating panel of MiniDiag. To deactivate: actuate button "0" and then "OK" on the operating panel of MiniDiag. | |
11 | Actuate back key on MiniDiag until the note "Switch off circuit 15" appears | The instructions in the MiniDiag should be observed during switching off and switching on of the ignition. The altered parameter should be stored permanently during switching off and switching on of the ignition. After switching on of the ignition the parameter should be checked for the "diffuser heater"; repeat the process for parameterizing if necessary. | |
12 | Detach MiniDiag |