Change data record, software, parameters in engine control (MR) control unit
21.08.2019
Engine
541.95, 900.92, 902.93, 924.93, 926.95/97 in model 000.001
with BlueTec
Engine
925.9 in model 000.001
with BlueTec
Modification notes
21.08.2019
Document completely revised.
Programming
1
Connect diagnostic system.
It is absolutely essential to precisely follow the operation steps as described in the diagnostic system. Ensure an adequate power supply from the batteries (greater than 24 V).
See information from body manufacturer. During programming: - do not start any other programs, - no European On-Board Diagnostics may run, - the engine must not run and must not be started, - the starter battery must not be disconnected.
2
Switch on ignition.
See information from body manufacturer.
3
Start diagnostic system.
Then Industrial engines Direct link for control units Engine control Control unit adaptations Parameterization Peripheral parameters Diffuser heater Select and confirm proportional valve 1.
4
Switch ignition off and on again
When the diagnostic system requests it.
5
Confirm "Transfer central data memory" using the F3 button.