AR01.10-P-0110HB | Crank engine with starter | 6.6.97 |
ENGINE 611.960 in MODELS 202.134 /133 /193 /194
ENGINE 611.961 in MODELS 210.006 /007 /206 /606
ENGINE 611.962 in MODELS 203.706 /204 /206 /006 /004
ENGINE 612.961 in MODELS 210.216 /016 /616
ENGINE 612.962 in MODEL 203.016
ENGINE 612.963 in MODEL 163.113
ENGINE 612.965 in MODELS 463.323 /322
ENGINE 612.966 in MODELS 461.345 /342 /302 /331 /332
ENGINE 612.967 in MODEL 209.316
ENGINE 612.990 in MODELS 203.018 /218 /718
ENGINE 613.961 in MODELS 210.026 /226
P01.10-0390-06
Shown on engine 611.960
01 Compression tester
02 Contact switch
8 Ignition/starter switch
Y74 Pressure regulator valve
Danger! | Risk of injury caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/rear-end door or sliding roof. | When moving components, ensure that no body parts or limbs are within the operating range of moving parts. | |
1 | Switch off ignition | Key in ignition / starter switch (8) in position 0. | |
2 | Open engine hood | Model 163.113 | |
Model 461.302/332/342/345 | |||
Model 461.331 | |||
3 | Disconnect electrical connector on pressure regulator valve (Y74) | To prevent injection of fuel. | |
4 | Connect compression recorder (01) | Only connect electric cables. See | |
Model 202.133/134/193/194 with engine 611.960 | |||
Model 210 with engines 611.961, 612, 613.961 | |||
Model 203 with engines 611.962, 612.962/990, model 209 with engine 612.967 | |||
Model 163 with engine 612 | |||
Models 463.322 /323 with engine 322/323612.965 | |||
Model 461.302/331/332/342/345 with engine 612.966 | |||
Danger! | Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns when working in engine during starting procedure | Secure vehicle to prevent it from moving. | |
5 | Crank engine | Do not crank the engine with the electronic ignition switch (8) but use the contact switch (02) on the compression tester (01) instead. | |
| |||
6 | Connect up electrical connector on pressure regulator valve (Y74) | ||
7 | Read out fault memory and erase | Stored faults which may result from wires being disconnected or from simulation during assembly or testing have to be processed and erased in the fault memories after completing the work. | |
| Connect up STAR DIAGNOSIS and read out fault memory | ||
Compression recorder
001 589 76 21 00
Commercially available tools