AP97.20-W-9780-01A | Perform cavity preservation on cab | ||
Danger | Risk of explosion and poisoning caused by solvent vapors and gasses. Risk of injury to skin and eyes when working with anticorrosion agents | Never spray corrosion protection on flames or hot, glowing objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection. | |
Topical note | Notes on cavity preservation |
Model | 930, 932, 933, 934, 940, 942, 943, 944, 949, 950.5/6, 952.5/6, 953.6, 954.5 |
with code XK8 (10-year anti-corrosion warranty) | |
Model | 959 |
with code X3T (6-year anti-corrosion warranty) | |
Model | 959 |
with code X3U (10-year anti-corrosion warranty) | |
Model | 970, 972, 974, 975, 976 |
with code XK8 (10-year anti-corrosion warranty) |
To spray the preservation agent, use a spraying hose Ø 6 mm.
Perform cavity preservation in area of front end
1 | Remove stop plugs from holes in front end area. |
2 | Insert spray hose into hole in front end area and push in direction of A-pillar. |
3 | When pulling out spray hose, spray hollow cavity with preservation agent. |
4 | Seal holes in front end area using stop plugs. |
Perform cavity preservation in entrance area
5 | Remove stop plugs from holes in entrance area. |
6 | Insert spray hose into hole in entrance area and push in direction of A-pillar or B-pillar. |
7 | When pulling out spray hose, spray hollow cavity with preservation agent. |
8 | Seal holes in entrance area using stop plugs. |
Perform cavity preservation in area of rear panel
9 | Remove stop plugs from holes in rear panel area. |
10 | Insert spray hose into hole in rear panel area and push in direction of B-pillar or center of cab. |
11 | When pulling out spray hose, spray hollow cavity with preservation agent. |
12 | Seal holes in rear panel area using stop plugs. |