AP86.10-T-8682A | Smoke alarm (lavatory) - replace battery | 10.11.09 |
MODEL NMB613.355 /358 /364 /365 /367 /368 /388 /455 /485
with ARGUS smoke alarm Connect, Merten company
T86.10-0016-11
1 Smoke alarm
2 Security bolt
3 Function test button (with LED)
4 Baseplate
5 Battery
| Removing | ||
| Notes on smoke alarm | ||
1 | Unscrew safety bolt (2) | The smoke alarm (1) is located on the ceiling of the lavatory. | |
2 | Turn smoke alarm (1) counterclockwise and remove | ||
| Checking | ||
3 | Check installation date of smoke alarm (1) | The installation date is recorded on the surface which points towards the baseplate (4). If the smoke alarm is more than 10 years old: | |
Replace smoke alarm (1) and record new installation date on the surface which points towards the baseplate (4). | |||
| Clean | ||
4 | Wipe the outside of the smoke alarm (1) with a damp cloth | ||
5 | Remove dust carefully with a brush | ||
| Install | ||
6 | Replace battery (5) | ||
7 | Install the smoke alarm (1) on the baseplate (4) and turn clockwise as far as the end stop | ||
8 | Screw in safety screw (2) | ||
Checking | |||
Danger! | Risk of injury caused by the loud acoustic warning from the smoke alarm | Wear hearing protection and close lavatory door. | |
9 | Press on function test button (3) for at least 1 s | A pulsating acoustic warning must sound during actuation. At the same time the LED in the function test button (3) must flash, otherwise: | |
Check battery and battery terminal, if necessary replace smoke alarm (1) |