ap8355t8311ab

Air conditioning - checking oil level in refrigerant compressor

ประเภท ap · หัวข้อ 83.55 · เวอร์ชัน 0102 · 2019-10-09

ใช้กับ: Model NMB671.030 with engine 457.942 with code HKC (Sütrak AC 353 air conditioning without roof heater)'

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.55 A/C compressor — ซีรีส์ 671 (รุ่น 030)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.40 Refrigerant compressor — ซีรีส์ 671 (รุ่น 030)

ใช้กับเครื่องยนต์/เกียร์ด้วย: 457 942

AP83.55-T-8311AB

Air conditioning - checking oil level in refrigerant compressor

08.10.2019

Model

NMB671.030 with engine 457.942

with code HKC (Sütrak AC 353 air conditioning without roof heater)

Air conditioning - checking oil level in refrigerant compressor

1

Refrigerant compressor

2

Filling screw

3

Inspection glass

T83.55-0019-11

Check

Danger

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

1

Run engine and switch on air conditioning

See air conditioning system operating instructions.

2

Switch off air conditioning and engine after 20 minutes

3

After 5 min waiting time, check oil level through inspection glass (3) of refrigerant compressor (1)

The oil level is correct if the oil level in the inspection glass (3) is in the upper area.

If the oil level is too low, check the refrigerant compressor (1) for external leakage, and correct oil level if necessary:

To do so, perform steps 4 to 8 subject to separate repair order.

Adjust to correct level

4

Drain air conditioning system

Air conditioning

AR83.30-T-1780AB

5

Open filling screw (2)

6

Pour in missing quantity of oil for refrigerant compressor

Compressor oils (specification 362.0)

BB00.40-P-0362-00A


To prevent damage to refrigerant compressor,
only use oils that comply with the Specifications for Operating Fluids.

The oil for the refrigerant compressor is hygroscopic (moisture absorbing). Immediately close the oil reservoir tightly and pour the measured quantity of oil into the refrigerant compressor (1) immediately.

7

Screw in filling screw (2) with new seal

Bolt, refrigerant compressor oil replenishment

*BA83.55-N-1004-01G

8

Charge air conditioning system

AR83.30-T-1777AB

Refrigerant compressor

Number

Designation

ENGINE 457.942 in MODEL 671.030 with CODE HKC

BA83.55-N-1004-01G

Bolt, refrigerant compressor oil replenishment

3/8"

Nm

60

M221.5

Nm

100

M241.5

Nm

100

M261.5

Nm

80

เอกสารที่อ้างถึง