ap0020d004601ts

Bring up roller test mode on instrument cluster

ประเภท ap · หัวข้อ 00.20 · เวอร์ชัน 0100 · 2018-04-30

ใช้กับ: Model 907, 910

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 0 Overall › 00 Overall vehicle › 00.20 Maintenance, service system (FSS, ASSYST) — ซีรีส์ 907 · ซีรีส์ 910

EinPAS 21 Brakes/vacuum system/compressed-air system › 21.15 Service brake/vacuum system › 21.15.1 Basic information — ซีรีส์ 907 · ซีรีส์ 910

EinPAS 21 Brakes/vacuum system/compressed-air system › 21.16 Parking brake › 21.16.1 Basic information — ซีรีส์ 907 · ซีรีส์ 910

EinPAS 26 Active safety system › 26.20 Braking/traction control › 26.20.1 Basic information — ซีรีส์ 907 · ซีรีส์ 910

AP00.20-D-0046-01TS

Bring up roller test mode on instrument cluster

Model

907, 910

Bring up roller test mode on instrument cluster

1

"Back" button

2

Finger navigation pad

3

Multifunction display

D00.20-1160-76

1

Close hood, doors and sliding doors.

2

Switch electronic ignition lock control unit (EZS) to position "1" (circuit  15R).

3

Using swipe movements on the finger navigation pad (2) to select the "Total distance" standard display in the multifunction display (3).

4

Press and hold "Back" (1) button for 2 s and press on finger navigation pad (2).

The multifunction display (3) then shows the Workshop menu with the menu items: "Vehicle data", "Dynamometer test", "Change brakepad", "ASSYST PLUS".

5

Use swipe movements on the finger navigation pad (2) to select the "Roller test" menu item on the multifunction display (3).

The "Roller test" menu item and "Switch on: OK " are shown on the multifunction display (3).

6

Switch on roller test mode by pressing the finger navigation pad (2).

On the multifunction display (3), a tick is placed next to "Roller test" and "Switch off: OK" is shown.

7

After completion of the roller test, switch off roller test mode by pressing on the finger navigation pad (2) again.

8

Press "Back" (1) button repeatedly until the "Total distance" standard display appears in the multifunction display (3).