an8370d000202ts

Prepare radio remote control wiring harness for retrofit

ประเภท an · หัวข้อ 83.70 · เวอร์ชัน 0101 · 2020-05-01

ใช้กับ: Model 907 with code H12 (Auxiliary hot-water heater) Model 910 with engine 651 with code H12 (Auxiliary hot-water heater)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — ซีรีส์ 651 · ซีรีส์ 907 · ซีรีส์ 910

EinPAS 39 Heating/ventilation/cooling › 39.25 Stationary heater/auxiliary heater › 39.25.3 Retrofitting/modification — ซีรีส์ 651 · ซีรีส์ 907 · ซีรีส์ 910

AN83.70-D-0002-02TS

Prepare radio remote control wiring harness for retrofit

Model

907

with code H12 (Auxiliary hot-water heater)

Model

910 with engine 651

with code H12 (Auxiliary hot-water heater)

Prepare radio remote control wiring harness for retrofit

000 589 13 99 00

Wiring harness repair kit, basic

Prepare radio remote control wiring harness for retrofit

1

Electric line

2

Electric line

3

Electric line

4

Plug housing

5

Cable lug

7

Contact receptacles

8

Female contact

D83.70-1570-03

The following line colors of the electric lines (1, 2, 3) correspond with the series production configuration and they can be substituted with similar line colors, if necessary. Please ensure that the electric lines (1, 2, 3) can be correctly assigned in accordance with the slot assignment.

1

Prepare electric line (1).

Line color "RD/BK", length approx. 160 cm, cross section 0.35 mm2.

2

Prepare electric line (2).

Model 910
Line color "GN/OG", length approx. 120 cm, cross section 0.35 mm2.

Model 907.### 1#
Line color "GN/OG", length approx. 180 cm, cross section 0.35 mm2.

Model 907.### 2#
Line color "GN/OG", length approx. 80 cm, cross section 0.35 mm2.

3

Fabricate electric line (3).

Model 907.### 1#, 910.### 1#
Line color "BN", length approx. 180 cm, cross section 0.35 mm2.

Model 907.### 2#, 910.### 2#
Line color "BN", length approx. 90 cm, cross section 0.35 mm2.

4

Crimp contact sockets (7) provided on one side onto electric lines (1, 2, 3).

Crimp contact sockets (7) on both sides onto electric line (2).

Use basic wiring harness repair kit.

5

Crimp contact socket (8) provided onto electric line (1).

Use basic wiring harness repair kit.

6

Install contact sockets (7) of electric lines (1, 2, 3) into plug housing (4) provided.

Slot assignment:
Slot 1: Electric line (3) "BN", slot 2: Electric line (2) "GN/OG", slot 3: Electric line (1) "RD/BK".

7

Crimp cable lug (5) provided onto electric line (3).

Use basic wiring harness repair kit.

8

Join electric lines (1, 2, 3) and wrap section-by-section using suitable insulation tape.

Ensure that the junctions of the electric lines (1, 2, 3) remain free at the connection end.