ad8370d4000f

Auxiliary heater (AHE) diagnosis fault memory

ประเภท ad · หัวข้อ 83.70 · เวอร์ชัน 0100 · 2003-06-13

ใช้กับ: MODEL 901.###, 902.###, 903.###, 904.### ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater Heater designation B3L-C compact, Heater designation D3L-C compact

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — ซีรีส์ 901 · ซีรีส์ 902 · ซีรีส์ 903 · ซีรีส์ 904

AD83.70-D-4000F

Auxiliary heater (AHE) diagnosis fault memory

21.7.98

MODEL 901.###, 902.###, 903.###, 904.### ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater
Heater designation B3L-C compact,
Heater designation D3L-C compact

Danger!

Risk of explosion due to fuel vapors, risk of poisoning from inhaling combustion gases and risk of injury from burns during or after heater operation

Do not start stationary heater/auxiliary heater with engine booster in confined spaces or while refueling. Allow heater to cool down after operation and wear safety gloves.

AS83.70-Z-0002-01A

Auxiliary heater (AHE) diagnosis, previous knowledge

AD83.70-D-2000D

I

Battery voltage > 10.5 volts

II

Auxiliary heater complete (all connectors connected)

III

Connect Hand-Held Tester (HHT)

AD00.00-D-2000-03A

IV

Ignition and auxiliary heater all switched on

Cables, plugs and connectors are also taken into account during testing with the HHT and, if a fault is displayed, may have to be checked again separately in accordance with the relevant electric wiring diagram for open circuit, good contact and correct connection

Fault memory

Fault code

Fault text (HHT)

Possible cause / remedy

Control module fault

Replace control module

Control module fault,

internal temperature sensor

Replace control module

Does not start

Check fuel supply, glow plug and flame sensor

Too many attempts at starting

Failure to start 10 times in succession (refer to code )

Flame goes out

Check fuel supply and quantity of fuel

If combustion is in order, check flame sensor

Overvoltage

Check regulating voltage

Undervoltage

Check fuse F9. Check battery and

regulating voltage.

Check electric cables (voltage drop)

Premature flame recognition

Check flame sensor

Flame sensor

–//–

Check flame sensor and replace if necessary

Metering pump

–//–

Check metering pump and replace if necessary

Check electrical cables and connections

Incorrect blower motor speed

Check blower motor, replace blower if necessary

Glow plug

–//–

Check glow plug, replace if necessary

Check electrical cables and connections

Overheating

Check hot air pipe inlet and outlet for obstruction, remove obstruction if necessary

Check overheating sensor

Frequent overheating

Check hot air pipe inlet and outlet for obstruction, remove obstruction if necessary

Check overheating sensor

Check flame sensor

Potentiometer

–//–

Check heater timer connections and replace timer if necessary

Overheating sensor

–//–

Outside tolerance

Check overheating sensor and replace if necessary

เอกสารที่อ้างถึง