ad5430d600010a

IC test of electrical system selector lever display

ประเภท ad · หัวข้อ 54.30 · เวอร์ชัน 0100 · 2003-06-10

ใช้กับ: MODEL 901, 902, 903, 904

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 54 Electrical system, equipment and instruments › 54.30 Instrument cluster, display instruments, hazard warning device — ซีรีส์ 901 · ซีรีส์ 902 · ซีรีส์ 903 · ซีรีส์ 904

EinPAS 31 Communication/information/entertainment › 31.30 Instrument cluster/onboard computer › 31.30.1 Basic information — ซีรีส์ 901 · ซีรีส์ 902 · ซีรีส์ 903 · ซีรีส์ 904

AD54.30-D-6000-10A

IC test of electrical system selector lever display

Scope of test

Measuring instrument/Test connection

Operation/

Requirement

Specified value

Possible cause/

Remedy

1.0

Selector lever display

Cable and instrument cluster

81

P

81a

N

4

3

2

Coupling disconnected at starter lockout switch

Ignition: ON

Plug one bridge at a time into starter lockout switch coupling

P

R

N

4

3

2

(With a deviation from specified value, check 1st gear microswitch)

Cables

Instrument cluster

1.1

Starter lockout switch

Resistance

81

P

81a

N

4

3

2

Ignition: OFF

Coupling disconnected at starter lockout switch

< 5 Ω

Starter lockout switch

1.2

Cables

2

1

7

9

10

11

12

Plug 3 disconnected from instrument cluster, plug housing open

Ignition: ON

Selector lever position:

P / R / N / 4 / 3 / 2 / 1

With a deviation

from specified value in selector lever position 1 or 2, check

1st gear microswitch

> 9.5 V

Cables

1.3

Selector lever display

(instrument cluster with speedometer)

Function

12

(1.7)

3

3

(1.5)

27

28

29

30

31

32

33

Instrument cluster removed

Adapter connected with adapter cable

Plug one bridge at a time into adapter cable

P

R

N

4

3

2

1

Instrument cluster

1.4

Selector lever display

(instrument cluster with tachograph)

Function

12

(1.7)

1

(1.4)

3

3

(1.5)

34

(3.5)

27

28

29

30

31

32

33

Instrument cluster removed

Adapter connected with adapter cable

Plug one bridge at a time into adapter cable

P

R

N

4

3

2

1

Instrument cluster