AD07.61-P-6002-14A | EPC malfunction indicator lamp, ME-SFI idle speed control/electronic accelerator electrical testing | up to 5/96 |
| Test of | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | EPC malfunction indicator lamp Actuation up to 5/96 Right ME-SFI control module only (N3/12) |
21 (1.21) | N3/12 |
35 (1.35) | Ignition: ON: Engine: Idle speed | 11 - 14 V < 1.0 V | Cable Fault in actuators or pedal value sensor ME-SFI control module (N3/12) |