AD07.61-P-6001-17C | Ignition voltage - Check ME-SFI ignition system electrics |
| Scope of test | Tester/test connection | Operation/ prerequisite: | Specified value | Possible cause/ remedy | ||
1.0 | Ignition voltage of the ignition coil (T1/1) up to (T1/3) | Engine tester | Test connection Secondary frame Measuring range 20 kV Time domain 100 % Connect kV sensor to T1/1 up to T1/3 in succession Starter: Actuate: | 8-20 kV | 1.1 Spark plugs ME-SFI control module (N3/10) | ||
1.1 | Secondary winding of T1/1, T1/2 and T1/3 |
Terminal 4a | T1/1 T1/2 T1/3 |
Terminal 4b | Disconnect both ignition leads at T1/1, T1/2 or T1/3 | 6-8.5 kΩ | T1/1, T1/2, T1/3 |