AD07.61-P-6000-03D | Starter relay, ME-SFI fuel injection system electrical testing | Models 170, 208 Model 202 as of 1.6.97 Model 210 as of 1.6.98 |
| Scope of test | Tester/test connection | Operation/ prerequisite | Specified value | Possible cause/ remedy | ||
1.0 | Starter relay N65 k2, K40/4k2 Actuation Models 170, 208 Model 202 as of 06/97 Model 210 as of 06/98 |
35 (3D) | N3/10 |
2 (2A) | Coolant temperature >20 °C Vehicle with AT Ignition/starter switch position3 (start position): Tap: Vehicle with MT Engine: Start: |
11 - 14 V or if engine will not start, approx. 5sec. 11 - 14 V during starting until engine speed >400 rpm, then <1V | 1.1 ME-SFI control module (N3/10) |
1.1 | Starter signal terminal 50 |
8 (8A) | N3/10 |
32 (40C) | Engine: Start: | 11 - 14 V during starting procedure | Cable Ignition/starter switch |