Air pump switchover valve, ME-SFI fault code description

ประเภท ad · หัวข้อ 07.61 · เวอร์ชัน 0102 · 2005-08-18

ใช้กับ: ENGINE 112.910 /911 /920 /921 /922 /940 /941 /942 /944 as of 1.6.00 ENGINE 112.912 /913 /914 /916 /917 /923 /943 /946 /947 /949 /953 /954 /955 /970 /972 /973 /975 ENGINE 113.940 /941 /942 /943 /960 as of 1.6.00 ENGINE 113.948 /961 /963 /964 /965 /966 /967 /968 /969 /971 ENGINE 112.945, 113.962 as of 1.11.00 in MODEL 463

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 1 Engine › 07 Mixture formation › 07.61 ME fuel injection/ ignition system — ซีรีส์ 463

EinPAS 15 Engine › 15.45 Engine management › 15.45.1 Basic information — ซีรีส์ 463

ใช้กับเครื่องยนต์/เกียร์ด้วย: 112 910, 112 911, 112 912, 112 913, 112 914, 112 916, 112 917, 112 920, 112 921, 112 922, 112 923, 112 940, 112 941, 112 942, 112 943, 112 944, 112 945, 112 946, 112 947, 112 949, 112 953, 112 954, 112 955, 112 970, 112 972, 112 973, 112 975, 113 940, 113 941, 113 942, 113 943, 113 948, 113 960, 113 961, 113 962, 113 963, 113 964, 113 965, 113 966, 113 967, 113 968, 113 969, 113 971

AD07.61-P-4000-78A

Air pump switchover valve, ME-SFI fault code description

Air pump switchover valve

1

Fault code

( Display on generic scan tool)

P2024 (P0412)

2

Fault storage

Activation of the engine diagnosis indicator lamp (EURO3/4)

or CHECK ENGINE (MIL) malfunction indicator lamp

After expiry of test duration and fault

Following two successive driving cycles with faults

3

Checking frequency

Continuous

4

Checked signal or status

Current/ voltage test at air pump switchover valve

5

Fault setting conditions

Limit values

Short circuit to ground

Short-circuit to +12 V

Line interruption

Voltage lower than 2.5 V

Current higher than 4.2 A

No voltage at air pump switchover valve

Approx. 4 to 8 V at output of ME-SFI control unit under no load.

6

Check prerequisites

Battery voltage between 8 and 17 V

7

Actuation of each air pump switchover valve is checked for detection of a line interruption or short-circuit (to ground or battery voltage). A short circuit to ground and a line interruption will be detected when the output stages are locked, whilst a short circuit to the battery voltage will be detected when the output stages are conducting.

The output stage is immediately no longer activated when a fault arises.