1 | Fault code | right cylinder bank left cylinder bank |
2 | Fault memory and actuation of CHECK ENGINE (MIL) | After two consecutive journeys with fault |
3 | Frequency of testing | Continuous |
4 | Checked signal or status | Voltage or current at respective adjustable camshaft timing solenoid |
5 | Limit values Short-circuit to ground Short-circuit to approx. 12 V Cable open-circuit |
Voltage < 4 V Current > 4.2 A No voltage (approx. 4-8 V) |
6 | Test conditions | Adjustable camshaft timing active |