O2 sensor heater (G3/3 to G3/6), heat output is too low | ||
1A | Fault code ( Readout on generic scan tool) | P2008 Right O2 sensor upstream of TWC (G3/4) (P0135) P2009 Right O2 sensor downstream of TWC (G3/6) (P0141) P2088 Left O2 sensor upstream of TWC (G3/3) (P0155) P2089 Left O2 sensor downstream of TWC (G3/5) (P0161) |
1B | Engines 112, 113 as of 1/01 Fault code ( Readout on generic scan tool) | P2008-[8] Right O2 sensor upstream of TWC (G3/4) (P0135) P2009-[8] Right O2 sensor downstream of TWC (G3/6) (P0141) P2088-[8] Left O2 sensor upstream of TWC (G3/3) (P0155) P2089-[8] Left O2 sensor downstream of TWC (G3/5) (P0161) |
2 | Fault storage Actuation of the engine diagnosis indicator lamp (EURO3/4) or CHECK ENGINE (MIL) | after expiry of test duration and fault following two successive driving cycles with faults |
3 | Checking frequency | Continuous |
4 | Checked signal or status | Internal resistance of the Nernst cells (generate the O2 sensor signal) |
5 | Fault setting conditions O2 sensors upstream of TWC O2 sensors downstream of TWC |
OK if the calculated resistance value for a hot O2 sensor is 130 to 580 Ω (model 170: 130 to 480 Ω). OK if the calculated resistance value for a hot O2 sensor is 160 to 1020 Ω (model 170: 160 to 770 Ω). |
6 | Check prerequisites | Exhaust and catalytic converter temperature 380 to 560°C |
7 | | The internal resistance of Nernst cells is used as a criterion for the testing. The internal resistance of Nernst cells must be within tolerance for the specified exhaust and catalytic converter temperature. If a fault on voltage supply for O2 sensor heater is also stored then first check the voltage supply (connector, line, fuse). In cases of a fault on the O2 sensor heater check: 1) Connector, line and fuse. 2) For a short circuit to ground: measure the resistor between the O2 sensor housing and the sensor heater (connection 1 or 2). Replace the O2 sensor if the resistance is less than 100 Ω. 3) For a short circuit to battery voltage: check the cold resistance (+25°C) of the sensor heater between connection 1 and 2. Replace the O2 sensor if the resistance is less than 4.5 Ω. 4) For line discontinuity: check the cold resistance (+25°C) of the sensor heater between connection 1 and 2. Replace the O2 sensor if the resistance is greater than 12 Ω. Use of cleaning or greasing fluids (sprays) and evaporating greases on the O2 sensor or the screw-in thread is not permissible. The screw-in thread must only be lubricated using the released grease. Broaching of the sensor lines is not permissible. |
P07.61-2557-01
View of electrical connection for O2sensor
1 Sensor heating
2 Sensor heating ground
3 Ground O2 sensors signal
4 O2 sensor signal