ad0761p400006a

Fault code description - ME-SFI - oxygen sensor signal

ประเภท ad · หัวข้อ 07.61 · เวอร์ชัน 0104 · 2003-06-06

ใช้กับ: ENGINES 112.910, 112.911 up to 31.5.00, 112.920, 112.921 up to 31.5.00, 112.923, 112.940 /941 /942 up to 31.5.00, 112.943 ENGINES 113.940 /942 /943 up to 31.5.00, 113.961 ENGINES 112.945, 113.962 up to 30.11.00 in MODEL 463

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 1 Engine › 07 Mixture formation › 07.61 ME fuel injection/ ignition system — ซีรีส์ 463

EinPAS 15 Engine › 15.45 Engine management › 15.45.1 Basic information — ซีรีส์ 463

ใช้กับเครื่องยนต์/เกียร์ด้วย: 112 910, 112 911, 112 920, 112 921, 112 923, 112 940, 112 941, 112 942, 112 943, 112 945, 113 940, 113 942, 113 943, 113 961, 113 962

AD07.61-P-4000-06A

Fault code description - ME-SFI - oxygen sensor signal

1

Fault code

on right upstream of TWC

on right downstream of TWC (only for and EURO3/4, not for Model 463)

on right upstream of TWC

on left upstream of TWC

on left downstream of TWC (only for and EURO3/4, not for Model 463)

on left upstream of TWC

2

Fault storage

Activation of malfunction indicator lamp for engine diagnosis (EURO3/4)

or CHECK ENGINE (MIL)

after the end of the test period and faults

after two successive driving cycles with faults

3

Frequency of the test

continuous

4

Checked signal or status

A. Limits for oxygen sensor signal

B. Sensor status change

5

Fault setting conditions

A. Limits for oxygen sensor signal

Lower limit

Upper limit

Test duration

B. Sensor status change

Voltage must not be less than -0.15 V

Voltage must not be greater than 1.5 V

approx. 5 s

After approx. 220 s with sensor heating switched on, the sensor signal must not dwell

in the voltage window 0.4 - 0.6 V for longer than approx. 15 s.

6

Test prerequisites

- engine speed approx. 1000 - 2000 rpm

- load approx. 15 - 50 %

- three-way catalytic converter temperature > 380 °C

- lambda control enabled

7

The following electrical connection faults of the oxygen sensors upstream and downstream of TWC are detected by the tests: line interruption, short circuit and shunt (high-resistance short circuit) to ground or battery voltage.

Line for oxygen sensor signal has shunt or limited voltage increase in oxygen sensor signal

Interruption of oxygen sensor signal ground.

With cold oxygen sensor, shunt to +12V or ground of ME-SFI control module.

With short circuit of oxygen sensor ground to +12 V, the ME-SFI control module is destroyed!

Fault code description - ME-SFI - oxygen sensor signal

P07.61-2531-11

Sensor back voltage, shown on Engine 137

G3/11 Left oxygen sensor downstream of TWC, cylinders 7 - 9

x1 Connector

1 Sensor heating terminal 87

2 Sensor heating ground

3 Sensor signal ground

4 Sensor signal (approx. 0.45 V at λ = 1 and oxygen sensor at operating temperature)

N3/10 ME-SFI control module

4x Amplifier for sensor signal analysis circuit and sensor signal ground

0.268 V Back voltage with respect to ground (term. 31)

Z6/4 Connector sleeve for sensor signal ground (4 oxygen sensors, M137 only)

Z7/36 Terminal 87 connector sleeve

The ground for the sensor signal is increased at the ME-SFI control module to approx. +0.268 V compared to the general vehicle ground. The analysis circuit for the oxygen sensor signal outputs this "sensor back voltage" of approx. 0.268 V. If the oxygen sensor is cold, the sensor internal resistance (Nernst cell) must be high enough, irrespective of the mixture composition, for the oxygen sensor voltage to be initially the same as the back voltage.

By testing the back voltage, line interruption, short circuit and shunt (high-resistance short circuit) to ground or battery voltage will be detected.

With a short circuit of the sensor signal to ground, the ME-SFI control module switches the lambda control to open-loop operation (mean λ value). This prevents a high fuel consumption.