AD07.13-D-6000-28B | Testing starter lockout and backup lamp switch, electrical system, diesel injection system (EDC) |
| Scope of test | Tester/test connection | Action/prerequisites | Nominal value | Possible cause/remedy | ||
1.0 | Starter lockout and backup lamp switch (S65) Wiring |
18 | |
12 | Ignition: OFF Connector disconnected from control module Selector lever position P/N Selector lever position R/4/3/2/1 |
< 5 Ω Ω | Wiring Starter lockout and backup lamp switch (S65) |