AD00.19-N-9035BA | Fault code list for automatic gear control (AGS) control unit | 11.1.08 |
MODEL 375.3 with BODY 375.810
MODEL 950.5 /6, 952.5 /6, 953.6, 954.5 with BODY 940.899
Fault code | Fault code description |
0160 | CAN bus OFF |
0161 | Communication fault to control module FR drive control |
0167 | Communication fault to control module RS retarder control (RET) |
0168 | Communication fault to control module ABS anti-lock braking system |
0169 | Communication fault to control module INS Instrument |
0171 | Communication fault to control module AG automatic gear selection (AGE) |
0172 | Fault in data communication to vehicle CAN. |
0173 | Transmission CAN databus in single-wire mode |
0174 | Transmission CAN databus is not supplying any data. |
0176 | Failure of CAN message 'Throw-out travel specified value for clutch position control' |
0177 | Failure of CAN message 'Safe status of drive train' |
0361 | Failure of backup drive function |
0901 | Overvoltage at terminal 30-2 |
0902 | Undervoltage at terminal 30-2 |
0920 | Undervoltage at terminal 30-2 |
1001 | Supply voltage of position sensors has Overvoltage. |
1002 | Supply voltage of position sensors has Undervoltage. |
1010 | Internal control module error |
1011 | A checksum error occurred while reading out EEPROM. |
1012 | A checksum error occurred while reading out EEPROM. |
1015 | A checksum error occurred while reading out EEPROM. |
1016 | A checksum error occurred while reading out EEPROM. |
1097 | Software in control module is a test version. |
1098 | Control module is a test version. |
1099 | Test status mode of control module is active. |
1101 | Overvoltage at terminal 30-1 |
1102 | Undervoltage at terminal 30-1 |
1120 | Undervoltage at terminal 30-1 |
1220 | Ground cable of solenoid valves has Open circuit. |
1301 | Overvoltage at terminal 15 |
1302 | Undervoltage at terminal 15 |
1420 | The supply voltage of component Rpm sensor has Open circuit. |
1421 | The supply voltage of component Rpm sensor has Short circuit to ground. |
1422 | The supply voltage of component Rpm sensor has Short circuit to positive. |
1520 | Component Pressure sensor has Open circuit. |
1521 | Component Pressure sensor has Short circuit to ground. |
1522 | Component Pressure sensor has Short circuit to positive. |
1720 | Temperature sensor of hydraulic pump output stage has Short circuit to positive or Open circuit. |
1721 | Temperature sensor of hydraulic pump output stage has Short circuit to ground. |
1723 | The hydraulic pump output stage has excess temperature. |
1820 | Voltage of valve relay 1 cannot be activated. |
1821 | Voltage of valve relay 1 cannot be deactivated. |
1920 | Voltage of valve relay 2 cannot be activated. |
1921 | Voltage of valve relay 2 cannot be deactivated. |
2020 | Ground line of high current supply has Open circuit. |
3020 | Solenoid valve A92y1 has Open circuit or Short circuit to positive. |
3021 | Solenoid valve A92y1 has Short circuit to ground. |
3120 | Solenoid valve A92y2 has Open circuit or Short circuit to positive. |
3121 | Solenoid valve A92y2 has Short circuit to ground. |
3220 | Solenoid valve A92y3 has Open circuit or Short circuit to positive. |
3221 | Solenoid valve A92y3 has Short circuit to ground. |
3320 | Solenoid valve A92y4 has Open circuit or Short circuit to positive. |
3321 | Solenoid valve A92y4 has Short circuit to ground. |
3420 | Solenoid valve A92y5 has Open circuit or Short circuit to positive. |
3421 | Solenoid valve A92y5 has Short circuit to ground. |
3520 | Solenoid valve A92y6 has Open circuit or Short circuit to positive. |
3521 | Solenoid valve A92y6 has Short circuit to ground. |
3620 | Solenoid valve A92y7 has Open circuit or Short circuit to positive. |
3621 | Solenoid valve A92y7 has Short circuit to ground. |
3720 | Solenoid valve A92y8 has Open circuit or Short circuit to positive. |
3721 | Solenoid valve A92y8 has Short circuit to ground. |
3820 | Solenoid valve A92y9 has Open circuit or Short circuit to positive. |
3821 | Solenoid valve A92y9 has Short circuit to ground. |
4120 | 'Gear' sensor (SGG) has Open circuit. |
4121 | 'Gear' sensor (SGG) has Short circuit to ground. |
4122 | 'Gear' sensor (SGG) has Short circuit to positive. |
4143 | Operational fault of component 'Gear' sensor (SGG) |
4144 | Component 'Gear' sensor (SGG) not within permissible range of values |
4220 | 'Gate' sensor (SGE) has Open circuit. |
4221 | 'Gate' sensor (SGE) has Short circuit to ground. |
4222 | 'Gate' sensor (SGE) has Short circuit to positive. |
4243 | Operational fault of component 'Gate' sensor (SGE) |
4244 | Component 'Gate' sensor (SGE) not within permissible range of values |
4420 | 'Clutch' sensor (SKU) has Open circuit. |
4421 | 'Clutch' sensor (SKU) has Short circuit to ground. |
4422 | 'Clutch' sensor (SKU) has Short circuit to positive. |
4443 | Operational fault of component 'Clutch' sensor (SKU) |
4444 | Component 'Clutch' sensor (SKU) not within permissible range of values |
5020 | No signal from rpm sensor B113. |
5096 | Fault in speed sensor signal B113 |
5120 | No signal from rpm sensor B3. |
5121 | Rpm sensor B3 'Countershaft' has Short circuit to ground. |
5122 | Rpm sensor B3 'Countershaft' has Short circuit to positive or Open circuit. |
5196 | Fault in speed sensor signal B3 |
5220 | Vehicle speed signal missing. |
5296 | Vehicle speed signal is faulty. |
5320 | No signal from rpm sensor B113.1. |
5396 | Fault in speed sensor signal B113.1 |
6020 | Output or the lead of the hydraulic pump output stage has Open circuit. |
6021 | Output or the lead of the hydraulic pump output stage has Short circuit to ground. |
8090 | Plausibility fault with actual gear ratio of transfer case. |
8091 | Not transmission output speed |
8093 | Incorrect transmission type |
8094 | Direction of travel determined is implausible. |
8095 | Pressure buildup in unit too slow during system start |
8110 | Plausibility error of specified value 'Clutch position control' |
8117 | Plausibility error of specified value 'Minimum clutch learned value' |
8185 | Clutch position control fault |
8186 | Plausibility error due to clutch opening |
8187 | Plausibility error due to clutch closing |
8189 | Plausibility error of specified value 'Clutch travel' |