AD00.19-N-9012BA | Fault code list for gear control (GS) control unit | 11.1.08 |
MODEL 375.3 with BODY 375.810
MODEL 950.5 /6, 952.5 /6, 953.6, 954.5 with BODY 940.899
Fault code | Fault code description |
0160 | Vehicle CAN bus faulty |
0161 | Communication fault on vehicle CAN bus |
0162 | Communication fault with control unit FR drive control (FMR) |
0163 | Communication fault with control unit PSM Parameterizable Special Module |
0164 | Communication fault with control unit WSK torque converter-clutch |
0165 | Communication fault with control unit RS retarder control (RET) |
0166 | Communication fault with control unit ABS anti-lock braking system or BS brake control (EPB) |
0167 | Communication fault with control unit INS Instrument |
0168 | Communication fault with control unit KS clutch control (MKR) |
0169 | Communication fault with control unit AG automatic gear selection (AGE) |
0170 | Communication fault with control unit MR engine control (PLD) |
1010 | Internal fault in control unit |
1011 | Learning data invalid |
1012 | Control unit GS gear control (EPS) is incorrectly parameterized. |
1080 | TEST electronics |
1082 | Test bench mode active |
1101 | Overvoltage at terminal 30 |
1102 | Undervoltage at terminal 30 |
1201 | Ground cable for control module has fault Open circuit. |
1301 | Overvoltage at terminal 15 |
1302 | Undervoltage at terminal 15 |
1503 | Voltage supply for shift control unit has fault Open circuit. |
1504 | Voltage supply for shift control unit and rotary sensor B57 has fault Short circuit to ground. |
1505 | Voltage supply for shift control unit and rotary sensor B57 has fault Short circuit to positive. |
2030 | Communication fault with shift control unit |
2031 | Ground cable for shift control unit has fault Open circuit. |
2032 | Cable for emergency shift has fault Open circuit. |
2033 | Cable for emergency shift has fault Short circuit to ground. |
2034 | Cable for emergency shift has fault Short circuit to positive. |
2035 | Enable fault emergency shift electronics |
2036 | Emergency shift has failed. |
2037 | Feedback output stage is faulty. |
3020 | Valve block GS (EPS), solenoid valve MS1 has fault Open circuit. |
3021 | Valve block GS (EPS), solenoid valve MS2 has fault Open circuit. |
3022 | Valve block GS (EPS), solenoid valve MS1 has fault Short circuit to ground. |
3023 | Valve block GS (EPS), solenoid valve MS2 has fault Short circuit to ground. |
3024 | Valve block GS (EPS), solenoid valve MS1 has fault Short circuit to positive. |
3025 | Valve block GS (EPS), solenoid valve MS2 has fault Short circuit to positive. |
3120 | Valve block GS (EPS), solenoid valve MUB has fault Open circuit. |
3121 | Valve block GS (EPS), solenoid valve MGB has fault Open circuit. |
3122 | Valve block GS (EPS), solenoid valve MUB has fault Short circuit to ground. |
3123 | Valve block GS (EPS), solenoid valve MGB has fault Short circuit to ground. |
3124 | Valve block GS (EPS), solenoid valve MUB has fault Short circuit to positive. |
3125 | Valve block GS (EPS), solenoid valve MGB has fault Short circuit to positive. |
3220 | Valve block GS (EPS), solenoid valve MUE has fault Open circuit. |
3221 | Valve block GS (EPS), solenoid valve MGE has fault Open circuit. |
3222 | Valve block GS (EPS), solenoid valve MUE has fault Short circuit to ground. |
3223 | Valve block GS (EPS), solenoid valve MGE has fault Short circuit to ground. |
3224 | Valve block GS (EPS), solenoid valve MUE has fault Short circuit to positive. |
3225 | Valve block GS (EPS), solenoid valve MGE has fault Short circuit to positive. |
3320 | Valve block GS (EPS), solenoid valve MG1 has fault Open circuit. |
3321 | Valve block GS (EPS), solenoid valve MG2 has fault Open circuit. |
3322 | Valve block GS (EPS), solenoid valve MG1 has fault Short circuit to ground. |
3323 | Valve block GS (EPS), solenoid valve MG2 has fault Short circuit to ground. |
3324 | Valve block GS (EPS), solenoid valve MG1 has fault Short circuit to positive. |
3325 | Valve block GS (EPS), solenoid valve MG2 has fault Short circuit to positive. |
3420 | Valve block GS (EPS), solenoid valve MR1 has fault Open circuit. |
3421 | Valve block GS (EPS), solenoid valve MR2 has fault Open circuit. |
3422 | Valve block GS (EPS), solenoid valve MR1 has fault Short circuit to ground. |
3423 | Valve block GS (EPS), solenoid valve MR2 has fault Short circuit to ground. |
3424 | Valve block GS (EPS), solenoid valve MR1 has fault Short circuit to positive. |
3425 | Valve block GS (EPS), solenoid valve MR2 has fault Short circuit to positive. |
3803 | Common ground cable of the solenoid valves has fault Open circuit. |
3804 | Common ground cable of the solenoid valves has fault Short circuit to ground. |
3805 | Common ground cable of the solenoid valves has fault Short circuit to positive. |
4040 | 'Splitter' sensor has fault Open circuit. |
4041 | 'Splitter' sensor has fault Short circuit to ground. |
4042 | 'Splitter' sensor has fault Short circuit to positive. |
4043 | Operational fault of component Splitter sensor |
4044 | Component Splitter sensor not within permissible range of values |
4140 | 'Gear' sensor has fault Open circuit. |
4141 | 'Gear' sensor has fault Short circuit to ground. |
4142 | 'Gear' sensor has fault Short circuit to positive. |
4143 | Operational fault of component Gear sensor |
4144 | Component Gear sensor not within permissible range of values |
4240 | 'Gate' sensor has fault Open circuit. |
4241 | 'Gate' sensor has fault Short circuit to ground. |
4242 | 'Gate' sensor has fault Short circuit to positive. |
4243 | Operational fault of component Gate sensor |
4244 | Component Gate sensor not within permissible range of values |
4340 | 'Range' sensor has fault Open circuit. |
4341 | 'Range' sensor has fault Short circuit to ground. |
4342 | 'Range' sensor has fault Short circuit to positive. |
4343 | Operational fault of component Range sensor |
4344 | Component Range sensor not within permissible range of values |
4440 | Clutch travel sensor has fault Open circuit. |
4441 | Clutch travel sensor has fault Short circuit to ground. |
4442 | Clutch travel sensor has fault Short circuit to positive. |
4443 | Operational fault of component Clutch travel sensor |
4444 | Component Clutch travel sensor not within permissible range of values |
5040 | No signal from rotary sensor B57. |
5043 | Operational fault of component B57 |
5140 | No signal from rotary sensor B3. |
5141 | Speed sensor B3 for countershaft has fault Short circuit to ground. |
5142 | Rpm sensor B3 for countershaft has fault Open circuit or Short circuit to positive. |
5143 | Operational fault of component Speed sensor for countershaft |
5240 | No C3 signal / speed pulse |
5243 | Fault in C3 signal / speed pulse |
5340 | No signal from rotary sensor B99. |
5343 | Operational fault of component B99 |
8091 | No rpm |
8092 | Transfer case incorrect or not parameterized |
8093 | Incorrect transmission type |
8094 | Direction of travel determined is implausible. |
8095 | Clutch position: below minimum learned value |
8096 | Clutch position: above maximum learned value |