ar2000p114501m

Actuate circulation pump

Typ ar · ämne 20.00 · version 0103 · 2006-08-18

Gäller för: ENGINE 275.950 in MODEL 215.376, 220.176 /876 ENGINE 275.980 in MODEL 215.379, 220.179

Inte tillgängligt på ”sv”; visas på Engelska.

Placering

Funktionsgrupp 1 Motor › 20 Motorkylning › 20.00 Allmänt — Serie 215 (modeller 376, 379) · Serie 220 (modeller 176, 179)

EinPAS 15 Motor › 15.25 Motorkylsystem › 15.25.30 Pump/termostat/förvärmningsaggregat — Serie 215 (modeller 376, 379) · Serie 220 (modeller 176, 179)

Gäller även motorer/växellådor: 275 950, 275 980

AR20.00-P-1145-01M

Actuate circulation pump

Actuate circulation pump
Actuate circulation pump

285 589 01 21 00

NTKL Adapter

Cooler vacuum filling device

285 589 00 21 00

Actuate circulation pump

P20.00-2118-04

1 Open the engine fuse and relay box (K40/8).

2 Remove the charge air relay (K40/8kW) from the engine fuse and relay box (K40/8).

3 Plug in the switch (included with the delivery of the cooler vacuum filling device ) in the plug position of the charge air relay (K40/8kW).

Activate the switch to actuate the circulation pump . A lamp will light up on the switch when the circulation pump is actuated .