be0702p100001a

Diesel fuel pump

Vrsta be · tema 07.02 · različica 0104 · 2013-03-11

Velja za: ENGINE 601, 603, 604, 605

Ni na voljo v jeziku »sl«; prikazano v jeziku Angleščina.

Umestitev

Funkcijska skupina 1 Motor › 07 Priprava mešanice › 07.02 Vbrizgalna črpalka, vtična črpalka, visokotlačna črpalka — Serija 601

EinPAS 16 dovajanje goriva/napajanje z energijo, motor › 16.10 dovajanje goriva › 16.10.32 enota za dovajanje/črpalka — Serija 601

Velja tudi za motorje/menjalnike: 603 ***, 604 ***, 605 ***

BE07.02-P-1000-01A

Diesel fuel pump

ENGINE

601, 603, 604, 605

Check values for diesel fuel pump

Number

Designation

Engine 601

Engine 603

BE07.02-P-1001-01A

Starting speed (with jumper cables)

1/min

>150

>150

BE07.02-P-1002-01A

Delivery rate (glow start switch at position "0")

Measurement duration

s

30

30

–

cm³

>150

>150

BE07.02-P-1003-01A

Delivery rate (at idle speed)

Measurement duration

s

–

–

–

cm³

–

–

BE07.02-P-1004-01A

Permissible loss in vacuum - entire system

Test pressure

mbar

–400...50

–400...50

Pressure loss

mbar/min

6

6

BE07.02-P-1005-01A

Permissible loss in vacuum - separate parts

Test pressure

mbar

–300...50

–300...50

Pressure loss

mbar/min

5

5

Check values for diesel fuel pump

Number

Designation

Engine 604

Engine 605.910

BE07.02-P-1001-01A

Starting speed (with jumper cables)

1/min

–

–

BE07.02-P-1002-01A

Delivery rate (glow start switch at position "0")

Measurement duration

s

–

–

–

cm³

–

–

BE07.02-P-1003-01A

Delivery rate (at idle speed)

Measurement duration

s

15

15

–

cm³

>250

>200

BE07.02-P-1004-01A

Permissible loss in vacuum - entire system

Test pressure

mbar

–400...50

–400...50

Pressure loss

mbar/min

6

6

BE07.02-P-1005-01A

Permissible loss in vacuum - separate parts

Test pressure

mbar

–300...50

–300...50

Pressure loss

mbar/min

5

5

Check values for diesel fuel pump

Number

Designation

Engine 605.911

BE07.02-P-1001-01A

Starting speed (with jumper cables)

1/min

>150

BE07.02-P-1002-01A

Delivery rate (glow start switch at position "0")

Measurement duration

s

15

–

cm³

>150

BE07.02-P-1003-01A

Delivery rate (at idle speed)

Measurement duration

s

–

–

cm³

–

BE07.02-P-1004-01A

Permissible loss in vacuum - entire system

Test pressure

mbar

–400...50

Pressure loss

mbar/min

6

BE07.02-P-1005-01A

Permissible loss in vacuum - separate parts

Test pressure

mbar

–300...50

Pressure loss

mbar/min

5