ar9140p061105a

Deployment of emergency tensioning retractor units when no deployment device is present

Vrsta ar · tema 91.40 · različica 0119 · 2012-05-14

Velja za: MODEL 163, 168, 170, 202, 203, 208, 209, 210, 215, 220, 230, 414, 463.200 /204 /206 /207 /208 /209 /220 /221 /222 /224 /225 /227 /228 /230 /231 /232 /233 /240 /241 /243 /244 /245 /246 /247 /248 /249 /250 /254 /300 /303 /304 /306 /307 /308 /309 /320 /321 /322 /323 /324 /325 /327 /328 /330 /331 /332 /333 /336 /340 /341, 901, 902, 903, 904, 905 MODEL WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7 MODEL 463.202 /236 /237 /346 up to Model Year 2013 /MOPF 201

Ni na voljo v jeziku »sl«; prikazano v jeziku Angleščina.

Umestitev

Funkcijska skupina 3 Nadgradnja › 91 Sedeži, ležišča, zadrževalni sistem › 91.40 Varnostni pasovi, zateznik varnostnih pasov — Serija 163 · Serija 168 · Serija 170 · Serija 202 · Serija 203 · Serija 208 · Serija 209 · Serija 210 · Serija 215 · Serija 220 · Serija 230 · Serija 414 · Serija 463 (modeli 200, 202, 204, 206, 207, 208, 209, 220, 221, 222, 224, 225, 227, 228, 230, 231, 232, 233, 236, 237, 240, 241, 243, 244, 245, 246, 247, 248, 249, 250, 254, 300, 303, 304, 306, 307, 308, 309, 320, 321, 322, 323, 324, 325, 327, 328, 330, 331, 332, 333, 336, 340, 341, 346) · Serija 901 · Serija 902 · Serija 903 · Serija 904 · Serija 905

EinPAS 27 pasivna varnost/zadrževalni sistemi › 27.17 zadrževalni sistem › 27.17.20 varnostni pas/zaklep varnostnega pasu/zateznik varnostnega pasu — Serija 163 · Serija 168 · Serija 170 · Serija 202 · Serija 203 · Serija 208 · Serija 209 · Serija 210 · Serija 215 · Serija 220 · Serija 230 · Serija 414 · Serija 463 (modeli 200, 202, 204, 206, 207, 208, 209, 220, 221, 222, 224, 225, 227, 228, 230, 231, 232, 233, 236, 237, 240, 241, 243, 244, 245, 246, 247, 248, 249, 250, 254, 300, 303, 304, 306, 307, 308, 309, 320, 321, 322, 323, 324, 325, 327, 328, 330, 331, 332, 333, 336, 340, 341, 346) · Serija 901 · Serija 902 · Serija 903 · Serija 904 · Serija 905

AR91.40-P-0611-05A

Deployment of emergency tensioning retractor units when no deployment device is present

Danger!

Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units.

Store airbag units with deployment side facing up; do not expose to temperatures above 100 °C. Interrupt the current supply when working on these units

AS91.00-Z-0001-01A

Model 163, 168, 170, 202 as of 1.7.93, 203, 208, 209, 210, 215, 220, 230, 414, 463

Danger!

Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units.

Store airbag units with deployment side facing up; do not expose to temperatures above 100 °C. Interrupt the current supply and disconnect airbag test connector/connector (AB) with emergency tensioning retractor (X11/13) when working on these units

AS91.00-Z-0001-01B

Model 202 up to 30.6.93

Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units

On model 163, 168, 170, 202, 203, 209, 208, 210, 215, 220, 230, 414, 463, not valid for

AH91.60-P-0611-02P

Ignition cable for firing airbag and seat belt tensioner units

WF58.50-P-9160-02A

Notes on disposing of airbag and emergency tensioning retractor units

All models

OS91.00-P-0001-01A

Use of self-fabricated ignition cable

1 Fabricate ignition cable with a length of 10 m with pressure switch.

2 Plug 2-pin plug coupling into the corresponding emergency tensioning retractor unit.

3 Connect ignition cable to battery.

4 Press both pressure switches at the same time.

Keep a distance of 10 m for safety.