ar8370d5937c

Removing and installing auxiliary heater control module

Vrsta ar · tema 83.70 · različica 0106 · 1999-04-19

Velja za: MODEL 901.0, 902.0, 903.0, 904.0, 901.3, 902.3, 903.3, 904.3, 901.4, 902.4, 903.4, 904.4 with CODE (H12) Hot water auxiliary heater MODEL 638.0 /1 /2 as of 13.10.97 with CODE (H12) Hot water auxiliary heater D5WS or B5WS

Ni na voljo v jeziku »sl«; prikazano v jeziku Angleščina.

Umestitev

Funkcijska skupina 3 Nadgradnja › 83 Klimatizacija › 83.70 Gretje na mestu, dodatno gretje, dogrevalniki — Serija 638 (modeli 0**, 1**, 2**) · Serija 901 (modeli 0**, 3**, 4**) · Serija 902 (modeli 0**, 3**, 4**) · Serija 903 (modeli 0**, 3**, 4**) · Serija 904 (modeli 0**, 3**, 4**)

EinPAS 39 gretje/zračenje/hlajenje › 39.25 gretje na mestu/dodatno ogrevanje › 39.25.11 krmilnik/rele — Serija 638 (modeli 0**, 1**, 2**) · Serija 901 (modeli 0**, 3**, 4**) · Serija 902 (modeli 0**, 3**, 4**) · Serija 903 (modeli 0**, 3**, 4**) · Serija 904 (modeli 0**, 3**, 4**)

AR83.70-D-5937C

Removing and installing auxiliary heater control module

29.4.97

MODEL 901.0, 902.0, 903.0, 904.0, 901.3, 902.3, 903.3, 904.3, 901.4, 902.4, 903.4, 904.4 with CODE (H12) Hot water auxiliary heater

MODEL 638.0 /1 /2 as of 13.10.97 with CODE (H12) Hot water auxiliary heater
D5WS or B5WS

Removing and installing auxiliary heater control module

D83.70-0068-06

1 Control module

2 Heater

3 Electrical connector

Removal, installation

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation

Do not start up or operate stationary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

Danger!

Fuel vapors present an explosion hazard. Fuel vapors are toxic when inhaled while handling open fuel. Contact with fuel can cause eye injury.

Fire, open lights and smoking prohibited. Avoid sparks. Fill and store fuel only in containers intended for this purpose.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

1

Disconnect ground lead from battery

Installation: Set timer to current time (see Eberspächer operating instructions)

2

Remove heater

Models 901.0, 902.0, 903.0, 904.0, 901.3, 902.3, 903.3, 904.3, 901.4, 902.4, 903.4, 904.4

AR83.70-D-5302F

Model 638

AR83.70-S-5335B

3

Unscrew screws

4

Pull control module (1) off of heater (2) until electrical connector (3) is accessible

5

Disconnect electrical connector (3) from control module (1)

6

Remove control module (1)

7

Reinstall in opposite order

8

Check stationary heater for proper function

Model 638

AR83.70-S-5302-02A

Povezani dokumenti