ar8370d117802a

Evaluating delivery quantity of fuel metering pump

Vrsta ar · tema 83.70 · različica 0100 · 1997-02-07

Velja za: MODEL 902.32 /42, 903.32 /42, 904.32 /42 with CODE (H11) Hot air auxiliary heater Heater designation D1L-C MODEL 903.02 with CODE (H11) Hot air auxiliary heater Heater designation B1L-C

Ni na voljo v jeziku »sl«; prikazano v jeziku Angleščina.

Umestitev

Funkcijska skupina 3 Nadgradnja › 83 Klimatizacija › 83.70 Gretje na mestu, dodatno gretje, dogrevalniki — Serija 902 (modeli 32*, 42*) · Serija 903 (modeli 02*, 32*, 42*) · Serija 904 (modeli 32*, 42*)

EinPAS 39 gretje/zračenje/hlajenje › 39.25 gretje na mestu/dodatno ogrevanje › 39.25.46 črpalka/posoda — Serija 902 (modeli 32*, 42*) · Serija 903 (modeli 02*, 32*, 42*) · Serija 904 (modeli 32*, 42*)

AR83.70-D-1178-02A

Evaluating delivery quantity of fuel metering pump

1 Enter voltage reading (V) on vertical axis in appropriate diagram.

2 Enter the quantity of fuel delivered in 90 sec. (in ml) on the horizontal axis in the appropriate diagram.

3 Determine intersection point of the two readings.

If the intersection point is within the two limits in the appropriate diagram, the fuel metering pump is okay.

Evaluating delivery quantity of fuel metering pump
Evaluating delivery quantity of fuel metering pump

D83.70-0025-01

Auxiliary heater D1L-C (diesel)

Auxiliary heater B1L-C (gasoline)

D83.70-0026-01