Remove/install pilot bushing of electrohydraulic controller unit

Vrsta ar · tema 27.19 · različica 0101 · 2012-02-21

Velja za: TRANSMISSION 722.681 in MODEL 902.6, 903.6, 904.6, 905.6 TRANSMISSION 722.681 in MODELS WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7

Ni na voljo v jeziku »sl«; prikazano v jeziku Angleščina.

Umestitev

Funkcijska skupina 2 Podvozje › 27 Samodejni menjalnik › 27.19 Elektrika, menjalnik — Serija 902 (modeli 6**) · Serija 903 (modeli 6**) · Serija 904 (modeli 6**) · Serija 905 (modeli 6**)

EinPAS 17 pogonski sklop/prema › 17.20 menjalnik › 17.20.11 krmilnik/rele — Serija 902 (modeli 6**) · Serija 903 (modeli 6**) · Serija 904 (modeli 6**) · Serija 905 (modeli 6**)

EinPAS 17 pogonski sklop/prema › 17.20 menjalnik › 17.20.35 krmilna enota/krmilno ohišje/plošča razdelilnika olja — Serija 902 (modeli 6**) · Serija 903 (modeli 6**) · Serija 904 (modeli 6**) · Serija 905 (modeli 6**)

Velja tudi za motorje/menjalnike: 722 681

AR27.19-D-4980A

Remove/install pilot bushing of electrohydraulic controller unit

15.2.12

TRANSMISSION 722.681 in MODEL 902.6, 903.6, 904.6, 905.6

TRANSMISSION 722.681 in MODELS WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7

Remove/install pilot bushing of electrohydraulic controller unit

D27.19-1124-04

1 O-rings

2 Pilot bushing

3 Screw

Remove/install

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

1

Disconnect battery ground line

Isolate ground lead to prevent accidental contact.

Notes on battery

AH54.10-P-0001-01A

2

Detach electrical connector.

AR27.19-D-0750-01B

3

Unscrew bolt (3) and remove pilot bushing (2)

Catch oil running out.
Replace O-rings (1).

4

Install in the reverse order