ap8610t8682a

Smoke alarm (lavatory) - replace battery

Vrsta ap · tema 86.10 · različica 0100 · 2009-11-18

Velja za: MODEL NMB613.355 /358 /364 /365 /367 /368 /388 /455 /485 with ARGUS smoke alarm Connect, Merten company

Ni na voljo v jeziku »sl«; prikazano v jeziku Angleščina.

Umestitev

Funkcijska skupina 3 Nadgradnja › 86 Oprema za nujne primere, oprema za ljudi s posebnimi potrebami, sanitarna oprema, kuhinja › 86.10 Obvezna oprema — Serija 613 (modeli 355, 358, 364, 365, 367, 368, 388, 455, 485)

EinPAS 27 pasivna varnost/zadrževalni sistemi › 27.21 sistem za gašenje/naprava za javljanje požara › 27.21.12 senzor/stikalo/kabelski snop — Serija 613 (modeli 355, 358, 364, 365, 367, 368, 388, 455, 485)

AP86.10-T-8682A

Smoke alarm (lavatory) - replace battery

10.11.09

MODEL NMB613.355 /358 /364 /365 /367 /368 /388 /455 /485
with ARGUS smoke alarm Connect, Merten company

Smoke alarm (lavatory) - replace battery

T86.10-0016-11

1 Smoke alarm

2 Security bolt

3 Function test button (with LED)

4 Baseplate

5 Battery

Removing

Notes on smoke alarm

AH86.10-N-0003-01A

1

Unscrew safety bolt (2)

The smoke alarm (1) is located on the ceiling of the lavatory.

2

Turn smoke alarm (1) counterclockwise and remove

Checking

3

Check installation date of smoke alarm (1)

The installation date is recorded on the surface which points towards the baseplate (4).

If the smoke alarm is more than 10 years old:

Replace smoke alarm (1) and record new installation date on the surface which points towards the baseplate (4).

Clean

4

Wipe the outside of the smoke alarm (1) with a damp cloth

5

Remove dust carefully with a brush

Install

6

Replace battery (5)

7

Install the smoke alarm (1) on the baseplate (4) and turn clockwise as far as the end stop

8

Screw in safety screw (2)

Checking

Danger!

Risk of injury caused by the loud acoustic warning from the smoke alarm

Wear hearing protection and close lavatory door.

AS86.10-Z-0003-01A

9

Press on function test button (3) for at least 1 s

A pulsating acoustic warning must sound during actuation. At the same time the LED in the function test button (3) must flash, otherwise:

Check battery and battery terminal, if necessary replace smoke alarm (1)

Povezani dokumenti