ad0000p200003b
Connecting Hand-Held Tester (HHT), reading out fault memory
Vrsta ad · tema 00.00 · različica 0103 · 2006-07-25
Velja za: MODEL 124 /, 129.060 /061 /066, 201 (except 124.034 /036)
Ni na voljo v jeziku »sl«; prikazano v jeziku Angleščina.
Umestitev
Funkcijska skupina 0 Celotno › 00 Celotno vozilo › 00.00 Splošno — Serija 124 (modeli 003, 004, 007, 008, 019, 020, 021, 022, 023, 026, 027, 028, 029, 030, 031, 032, 040, 041, 042, 043, 050, 051, 052, 060, 061, 062, 066, 079, 080, 081, 082, 083, 088, 090, 091, 092, 104, 105, 106, 107, 120, 125, 126, 127, 128, 129, 130, 131, 133, 180, 185, 186, 188, 190, 191, 193, 226, 230, 290, 330, 333, 393) · Serija 129 (modeli 060, 061, 066) · Serija 201
EinPAS 25 električno omrežje/omrežje/več funkcij › 25.15 omrežje/več funkcij › 25.15.1 osnovne informacije — Serija 124 (modeli 003, 004, 007, 008, 019, 020, 021, 022, 023, 026, 027, 028, 029, 030, 031, 032, 040, 041, 042, 043, 050, 051, 052, 060, 061, 062, 066, 079, 080, 081, 082, 083, 088, 090, 091, 092, 104, 105, 106, 107, 120, 125, 126, 127, 128, 129, 130, 131, 133, 180, 185, 186, 188, 190, 191, 193, 226, 230, 290, 330, 333, 393) · Serija 129 (modeli 060, 061, 066) · Serija 201
AD00.00-P-2000-03B
| Connecting Hand-Held Tester (HHT), reading out fault memory
| Models 124 except 124.034/036, 129.060/061/066, 201
|
|
Commercially available tools
Number
| Designation
|
|
WH58.30-Z-1036-13A
| Handheld tester (HHT)
| 651 100 01 99
|
WH58.30-Z-1037-13A
| Test cable (multiplexer)
| 651 100 40 99
|
1 Connect Hand-Held Tester (087) with test cable (Multiplexer) (094) to data link connector (X11/4).
2 Switch on ignition.
3 According to instructions on display:
a) Read out/erase fault memory
b) Read out actual values
c) Perform actuations
d) Program control modules
4 Disconnect HHT.
087 Hand-Held Tester (HHT)
094 Test cable (Multiplexer)
X11/4 Data link connector
Observe system-specific deviations which are listed for the appropriate diagnosis description in the chapter "Advanced information on diagnostics".
Stored faults which can be caused by disconnected cables or a simulation must be erased in the fault memory upon completion of the work.