ar8610p0101a

Remove/install fire extinguishing system control unit

Тип ar · тема 86.10 · версия 0101 · 2009-05-26

Применимость: MODEL 463.236 /248 with CODE (979) Special protection version with CODE (ZS6) Special protection version FB6 with fire extinguishing system MODEL 463.236 /248 with CODE (979) Special protection version with CODE (ZS7) Special protection version FB7 with fire extinguishing system

Нет на языке «ru»; показано на языке Английский.

Расположение

Функциональная группа 3 Кузов › 86 Аварийные устройства, реабилитационное оборудование, санитарная техника, кухня › 86.10 Аварийно-вспомогательные устройства — Серия 463 (модели 236, 248)

EinPAS 27 Системы пассивной безопасности / удержания пассажиров › 27.21 Система пожаротушения / система пожарной сигнализации › 27.21.11 Блок управления / реле — Серия 463 (модели 236, 248)

AR86.10-P-0101A

Remove/install fire extinguishing system control unit

30.4.09

MODEL 463.236 /248
with CODE (979) Special protection version
with CODE (ZS6) Special protection version FB6
with fire extinguishing system

MODEL 463.236 /248
with CODE (979) Special protection version
with CODE (ZS7) Special protection version FB7
with fire extinguishing system

Remove/install fire extinguishing system control unit

P86.10-2101-11

1 Plug connector

N100 Fire extinguishing system control unit

Remove/install

1

Disconnect ground line from battery (G1) with battery main switch (S25/20)

See Operator's Manual

2

Open flap on additional battery paneling (G1/3)

In load compartment on right side.

3

Disconnect connector (1) from fire extinguishing system control unit (N100)

4

Unscrew and remove fire extinguishing system control unit (N100) from rear wall

5

Install in the reverse order

6

Connect STAR DIAGNOSIS, read out DTC memory and erase if required

DTC's may be stored as a result of interrupted electrical connectors, simulation during removal and installation work or during test work. It is necessary to read these out and erase them with the STAR DIAGNOSIS diagnosis system.

Connect STAR DIAGNOSIS and read out fault memory

AD00.00-P-2000-04A

7

Perform basic programming

AR00.19-P-0200P

Связанные документы