P83.30-3564-06
1 Bolt
2 Bolt
3 Coolant line
4 Coolant line
5 Fluid reservoir
6 Bolt
7 Clamp
| Remove/install | ||
Danger! | Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning. Inhaling overheated refrigerant vapors may be toxic. Risk of injury from skin and eye contact with liquid refrigerant. | Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or open flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Procedures if air conditioning system is damaged or leaking | All models | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
| Notes on handling refrigerant R134a | All models fitted with air conditioning | |
1 | Evacuate air conditioning system | Installation: Refill air conditioning and check for proper operation and leaktightness. | |
2 | Remove fender liner in left-hand front fender | ||
3 | Remove bolt (1, 2) for coolant line (3, 4) at the fluid reservoir (5) | | |
4 | Remove coolant line (3, 4) from the fluid reservoir (5) | Installation: Install new sealing rings and moisten with compressor oil. | |
5 | Unscrew screw (6) at clamp (7) from fluid reservoir | ||
6 | Remove fluid reservoir (5) | Installation: Note additional oil filling capacity when replacing the fluid reservoir. | |
7 | Install in the reverse order |
Air conditioning system
Number | Designation | Model Series 163 | |
BA83.30-P-1001-01B | Hexagon bolt securing refrigerant line to fluid reservoir | NM | 10 |
Refrigerant compressor
Связанные документы
- ah8330n000301a Указания по обращению с хладагентом R134a
- ah8330n000401a Порядок действий при работе с поврежденным или негерметичным контуром системы кондиционирования
- ah8330n000501a При выполнении ремонтных работ защитить циркуляционный контур и детали кондиционера от воздействия влаги
- ar8330p1760gh Систему кондиционирования опорожнить, вакуумировать, заново заправить и проверить на функциональность и герметичность
- ar8810p1300gh
- as8300z000101a Опасность взрыва при выполнении сварочных или паяльных работ на неразгерметизированном контуре системы кондиционирования. Опас�