Test values for sliding doors
Number | Designation | Models | |
BE72.16-N-1002-01A | Distance between bottom end of paneling | mm | 30 |
D72.16-1189-09
Adjust height and/or inclination of sliding door
1 Open sliding door (1)
2 Check installation position of edge guard at front corner pillar, correct if necessary.
3 Unclip cover in interior compartment above sliding door (1) and remove.
4 Loosen nut (2) and turn downward
5 Lift sliding door (1) from outside
6 Turn bolts (3) until required height and/or inclination is reached.
7 Lower sliding door (1), close
8 Check dimension "a"at front and rear, repeat steps 5 to 8 if necessary.
9 Check inclination on basis of light shining in, repeat steps
5 to 9 if necessary
10 Tighten nut (2).
11 Insert covers in interior compartment above sliding door (1)
12 Check installation position of bottom carriage (4), correct if necessary.
D72.16-1190-06
Adjust evenness of sliding door
The sliding door (1) can only be moved in the bottom area to the pillars of the sliding door portal
13 Loosen nuts (5).
14 Move carriages (6) toward inside and outside
15 Tighten nut (5).
D72.16-1192-06
Adjust stop
16 Loosen bolts (7).
17 Open sliding door (1) to stop, if necessary correct position of door arrest (8)
18 Close sliding door (1)
19 Tighten bolts (7).