Workshop equipment
WE58.40-Z-1001-02A | Inert gas welder |
WE58.40-Z-1003-03A | Angle grinder (electric/pneumatic) |
Attaching
1 Weld retaining devices (31) in center bead (32) of side wall paneling on exterior side with gap a (arrow), .
Dimension: a = 200 mm (measured from edge (30))
Attach retaining devices only with individual spot welds. It is necessary to separate the welding connection between the retaining devices (31) and the side wall paneling for removing the retaining devices.
L63.10-0013-03
2 Position rectangular channel (33) on retaining devices (31) and weld (arrow), .
It is necessary to separate the welding connection between the rectangular channel (33) and the retaining devices (31) for removal of the retaining devices.
Detaching
3 Separate welding connections (34) between retaining devices (31) and side wall paneling.
L63.10-0014-03