AD07.61-S-6000-49A | Oil level indicator switch, testing electrical system, ME-SFI fuel injection system |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Oil level indicator switch B10 |
73 (17E) | A61 |
2 (2A) | Ignition: ON Oil level in order: Oil level too low: |
11 - 14 V < 1 V | B10 1.1 |
1.1 | Cable -//- Cable - Cable + | A61 73 (17E) |
|
B10 1 A61 73 (17E) A61 73 (17E) | Ignition: OFF Connector E on ME-SFI control module (A61) disconnected Connector B10 disconnected Ignition: OFF Connector E on ME-SFI control module (A61) disconnected Connector B10 disconnected Connector E on ME-SFI control module (A61) disconnected Connector B10 disconnected Ignition: ON |
< 5 Ω > 20 kΩ < 1 V | Test cable for –//– Test cable for - Test cable for + |