Valabil pentru: MODEL ALL with CODE MC7 (Engine OM 642 D 30 BlueTEC) MODEL ALL with CODE U42 (BlueTEC diesel exhaust treatment (SCR)) MODEL ALL with CODE U77 (Diesel Emission control BLUETEC (SCR))
with CODE U42 (BlueTEC diesel exhaust treatment (SCR))
MODEL
ALL
with CODE U77 (Diesel Emission control BLUETEC (SCR))
Modification notes
25.02.2015
Document content added and code U77 (BLUETEC (SCR) diesel exhaust treatment) added. Refilling AdBlue® as well as testing and diagnostic operations on the AdBlue® system due to a low AdBlue® tank level must not be invoiced under warranty.
One-way filling hose
P00.00-4715-01
The following filling options are now available with immediate effect:
One-way filling hose (picture):
This hose has a locking mechanism which enables drip-free filling to be performed. The fixed connection between the can and the AdBlue® container prevents any overfilling.
The one-way hose remains closed until it is fastened to the vehicle's AdBlue® filler neck.
2 Fit one-way filling hose to vehicle filler neck.
3 Screw on finger-tight in clockwise direction.
Do not tighten the one-way filling hose too much. Once a resistance is felt, the one-way filling hose is sufficiently tightened.
4 Lift can and place to one side. It may be necessary, to move the can to this position to enable the filling process to be performed. The AdBlue® container is full when the can is no longer being emptied.
5 After filling has been completed, carefully unscrew the one-way filling hose from the AdBlue® container first and then slowly detach it to ensure that the AdBlue® still in the bleed line can be drained off.
This helps to prevent any soiling.
5 l can:
This has the same locking thread as on the 10 l can.
The most varied types of AdBlue® containers are available on the market. The one-way filling hose however, is specially matched to our can. A reliable and drip-free filling process can only be guaranteed when this particular combination is chosen. Before the maintenance interval is reached: If the "Refill AdBlue" service indicator appears in the multifunction display before the maintenance interval is reached, both the refill bottle and the one-way filling hose with 5 l can is available.
We recommend that the customer be shown how to refill the tank in order to avoid the risk of contamination.
During maintenance, only the 10 l can of AdBlue® in combination with the one-way filling hose should be used!
Refilling AdBlue® as well as testing and diagnostic operations on the AdBlue® system due to a low AdBlue® tank level must not be invoiced under warranty. For this purpose, the filling capacities of the respective AdBlue® tank must also be observed.
It is essential to prevent overfilling of the AdBlue® tank. The AdBlue® tank can otherwise be damaged.