PE83.30-D-2001-60D | Legend of wiring diagram of climate control | MODEL 690.6 |
Short designation | Designation | Coordinate |
A200 | Thermotronic control unit | 26L |
B138 | Temperature sensor | 43A |
B138x1 | Temperature sensor connector | 43D |
B203 | Temperature sensor | A 30 |
F200 | Roof AC fuse (80 A) | 17E |
F201 | Roof AC blower 1 fuse (30 A) | 6J |
F202 | Roof AC blower 2 fuse (30 A) | 14H |
F203 | Roof AC fan fuse (30 A) | 35J |
F204 | Roof AC compressor fuse (7,5 A) | 27J |
F205 | Roof AC switch enable relay fuse (7,5 A) | 3G |
F206 | Tml. D+ relay fuse (7,5 A) | 2G |
G2 | Battery | 17A |
J46 | Circuit 58 connector sleeve | 4E |
J89 | Circuit 56b connector sleeve | 2E |
J460 | Roof AC switch connector sleeve | 11E |
J461 | Roof AC switch stage 2 connector sleeve | 9E |
J462 | AC ON connector sleeve | 41E |
J463 | Circuit 30 connector sleeve | 3E |
J464 | Fan/compressor enable connector sleeve | 22L |
J465 | Thermotronic compressor connector sleeve | 35G |
J466 | Blower 1 and 2 relay control unit connector sleeve | 11L |
J467 | Blower 1 and 2 relay output connector sleeve | 15L |
K201 | Roof AC blower stage 2 relay | 9L |
K203 | Roof AC blower stage 1 and 2 relay | 19L |
K204 | Roof AC blower stage 1 relay | 14L |
K205 | Roof AC fan relay | 37L |
K206 | Roof AC compressor relay | 31L |
K207 | Roof AC switch enable relay | 3L |
M200 | Blower motor | 33A |
S200 | Roof AC switch | 5A |
S201 | AC ON switch | 40A |
V18 | Thermotronic diode | 35A |
W4 | Ground point firewall | 16E |
W5 | Ground point seat frame | 1G |
W8 | Waistrail ground point | 5E |
X195 | Frame/engine connector | 36E |
X287 | Roof AC control unit connector | 18H |
X299 | Roof AC fan connector | 30H |
X300 | Roof AC switch connector | 5H |
X310 | Roof AC control unit | 20A |
X310b1 | High pressure switch | 23B |
X310b2 | Low pressure switch | 24B |
X310b3 | Temperature sensor | 26B |
X310b3x1 | Temperature sensor connector | 26 C |
X310m1 | Roof AC blower 1 | 19B |
X310m1x1 | Roof AC blower 1 connector | 18 C |
X310m2 | Roof AC blower 2 | 21B |
X310m2x1 | Roof AC blower 2 connector | 20 C |
X310x1 | Roof AC control unit connector | 18E |
X311 | Temperature sensor connector | 29E |
X312 | Temperature sensor connector | 30E |
X313 | Blower motor connector | 32E |
Y38 | Air conditioning compressor clutch | 37A |