gf8375p2110rt

Coolant circulation pump, component description

Tip gf · temă 83.75 · versiune 0102 · 2008-04-11

Valabil pentru: MODEL 251.1 /0 up to Model Year 8

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 3 Suprastructură › 83 Climatizare › 83.75 Instalaţia de căldură reziduală a motorului — Seria 251 (modele 0**, 1**)

GF83.75-P-2110RT

Coolant circulation pump, component description

23.5.05

MODEL 251.1 /0 up to Model Year 8

Coolant circulation pump, component description

P83.75-2010-06

M13 Coolant circulation pump

Location

The coolant circulation pump is located in the front right section of the engine compartment.

Task

The coolant circulation pump serves:
- for support when the engine is running or, with residual heat mode or stationary heater switched on (stationary heater, code 228), for pumping the coolant through the heater heat exchanger.

Function

The coolant circulation pump is controlled directly by the AAC control and operating unit (N22) or comfort AAC control and operating unit (N22/7).