P83.55-2325-08
1 | Air intake pipe | 4 | Refrigerant line | |
2 | Charge air pipe | 5 | Refrigerant line | |
3 | Poly-V-belt | A9/7 | Refrigerant compressor with magnetic clutch |
4 | Refrigerant line |
5 | Refrigerant line |
6 | Electrical connector |
7 | Bolts |
8 | Screw |
9 | Bracket |
A9/7 | Refrigerant compressor with magnetic clutch |
P83.55-2326-12
Danger | Risk of injury when working on air conditioning systems due to R744 refrigerant escaping under pressure. Risk of suffocation from inhaling R744 refrigerant in high concentrations. Health hazard caused by inhalation of R744 refrigerant | Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R744 | |||
| Remove/install | ||
1 | Drain air conditioning system | ||
2 | Remove air intake pipe (1) | ||
3 | Remove charge air pipe (2) | ||
Installation: Install new sealing rings. | |||
4 | Slacken poly-V-belt (3) and remove from belt pulley of refrigerant compressor with magnetic clutch (A9/7) | ||
5 | Lower steering | ||
6 | Disconnect electrical connector (6) | ||
7 | Remove refrigerant lines (4 and 5) at refrigerant compressor with magnetic clutch (A9/7) and close openings with stop plugs | Removal: | |
Installation: Replace gaskets. | |||
Screw, refrigerant line (CO2) to refrigerant compressor | |||
Record plug | |||
If damage (scratches, notches) occurs to the sealing surfaces | |||
| |||
Replace corresponding component. | |||
8 | Remove screws (7) and remove holder (9) | Screw/bolt, refrigerant compressor to timing case/crankcase/engine support | |
9 | Unscrew bolt (8) | Screw/bolt, refrigerant compressor to timing case/crankcase/engine support | |
10 | Remove refrigerant compressor with magnetic clutch (A9/7) upwards | | |
11 | Install in the reverse order | ||
12 | Perform break in of refrigerant compressor with magnetic clutch (A9/7) using diagnostic system | When replacing refrigerant compressor with magnetic clutch (A9/7). | |
|
129 589 00 91 00
Record plug
Documente menționate
- ad0000p200004b
- ah8330n000501a Protejarea circuitului şi componentelor instalaţiei de climatizare împotriva umidităţii la lucrările de reparaţie
- ah8330p000303a Indicaţii pentru lucrul cu refrigerentul R744
- ar0941p8620lfa Demontarea, montarea canalelor aer de supraalimentare
- ar1320p0001lfa Demontarea, montarea componentelor transmisiei prin curea
- ar4620p0600lf Demontarea, montarea casetei de direcţie cu pinion şi cremalieră
- ar8330p1760lf Golirea, evacuarea, umplerea din nou a instalaţiei de climatizare şi verificareaetanşeităţii şi funcţionării
- as8300z000801a Pericol de rănire la lucrări la instalaţia de climatizare provocată de scurgerea refrigerentului R744 aflat sub presiune. Pericol de asfixiere la inhalarea de refrigerent R744 în concentraţii mari. Pericol pentru sănătate prin inha