1 | Manual shutoff valve |
2 | Filter drier |
3 | Filling connection |
4 | Refrigerant line |
5 | Clip |
T83.50-0009-12
| Remove/install | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
1 | Remove cover of air conditioning system (roof-mounted) | ||
Observe accident prevention regulations when working in the roof area. | |||
2 | Close both manually operated shutoff valves (1) | The manually operated shutoff valves (1) are located under the protective nuts. | |
3 | Drain air conditioning system | ||
| |||
Installation: Evacuate closed-off circuit of the filter drier | |||
via filling valve: | |||
| |||
Evacuate air conditioning system, leak test | |||
By closing off the filter drier (2) from the rest of the air conditioning circuit, it is not necessary to refill refrigerant. | |||
If the filter drier (2) has been frequently replaced, it will be necessary to extract and refill the refrigerant: | |||
| |||
Discharge air conditioning system | |||
Fill air conditioning system (liquid) | |||
4 | Detach refrigerant lines (4) from filter drier (2) | ||
| Compressor oils (specification 362.0) | ||
Installation: | |||
Coat sealing rings with compressor oil before installation in accordance with Specifications for Operating Fluids. | |||
5 | Unfasten and detach clamp (5) | ||
6 | Detach filter drier (2) | Installation: | |
7 | Install in the reverse order | ||
8 | Perform function test | ||
|
Documente menționate
- ah8330n000301a Indicaţii pentru manipularea refrigerentului R134a
- ah8330n000401a Comportament dacă instalaţia de climatizare este avariată respectiv neetanşă
- ah8330n000501a Protejarea circuitului şi componentelor instalaţiei de climatizare împotriva umidităţii la lucrările de reparaţie
- ap8300t8352ba
- ap8300t8352bac
- ap8300t8352bad
- ap8300t8352baf
- ap8300t8352bas
- ar8330t1762c
- ar8330t1777c
- ar8330t1777c
- ar8330t1780c
- ar8350t500001b
- as8300z000101a Pericol de explozie datorită lucrărilor de lipire sau sudură la instalaţia de climatizare oprită. Pericol de otrăvire prin inhalarea de vapori de refrigerent supraîncălziţi. Pericol de rănire prin contactul pielii şi ochilor cu
- bb0040p036200a Uleiuri de compresor (specificaţie 362.0)