2 | Pressure-side testing and filling valve |
3 | Suction side testing and filling valve |
4 | Intake side shutoff valve |
T83.30-0061-06
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
1 | Open electromagnetic shutoff valve |
| |
Electric opening | |||
2 | Connect pressure and suction line of air conditioning vacuum and recycling unit to pressure side test and filling valve (2) and to intake side test and filling valve (3) | Observe operating instructions for air conditioning system vacuum and recycling unit. | |
3 | Unscrew cover cap from intake side shutoff valve (4) | ||
4 | Screw in intake side shutoff valve (4) approx. 3 turns | The intake side test and filling valve (3) is opened by the screwing-in process. | |
5 | Extract refrigerant via pressure side test and filling valve (2) and intake side test and filling valve (3) | Note the following: | |
6 | After emptying the air conditioning system, unscrew intake side shutoff valve (4) up to the end stop | By unscrewing up to the end stop, the intake side test and filling valve (3) is closed. | |
7 | Tighten cover cap on intake side shutoff valve (4) | ||
8 | Switch off air conditioning vacuum and recycling unit | ||
9 | Remove pressure and suction line of air conditioning vacuum and recycling unit |
Documente menționate
- ah8330n000301a Indicaţii pentru manipularea refrigerentului R134a
- ah8330n000401a Comportament dacă instalaţia de climatizare este avariată respectiv neetanşă
- ah8330n000501a Protejarea circuitului şi componentelor instalaţiei de climatizare împotriva umidităţii la lucrările de reparaţie
- ar8330t5460aa
- ar8330t5470bac
- as8300z000101a Pericol de explozie datorită lucrărilor de lipire sau sudură la instalaţia de climatizare oprită. Pericol de otrăvire prin inhalarea de vapori de refrigerent supraîncălziţi. Pericol de rănire prin contactul pielii şi ochilor cu