ar8330p6540mcc

Remove/install condenser

Tip ar · temă 83.30 · versiune 0101 · 2007-09-05

Valabil pentru: MODEL 451.3 /4 with CODE (I01) Air conditioning Plus

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 3 Suprastructură › 83 Climatizare › 83.30 Instalaţie de climatizare — Seria 451 (modele 3**, 4**)

EinPAS 39 Încălzire/Aerisire/Răcire › 39.15 Climatizare › 39.15.41 Condensator/Uscător/Răcitor gaz — Seria 451 (modele 3**, 4**)

AR83.30-P-6540MCC

Remove/install condenser

21.8.07

MODEL 451.3 /4 with CODE (I01) Air conditioning Plus

Remove/install condenser

P83.30-4474-05

1 Capacitor

2 Refrigerant line

3 Nut

4 Catch

Remove/install

Danger!

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged.

AS83.00-Z-0001-01A

Procedure for a damaged or leaky air conditioning system

AH83.30-N-0004-01A

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

1

Remove front module

AR62.30-P-1575MCC

2

Discharge air conditioning system

Installation: Evacuate air conditioning and then fill.

AR83.30-P-1760MCC

3

Unscrew nut (3) from condenser (1) and detach refrigerant lines (2) from condenser (1)

Close off refrigerant lines (2) and condenser (1) using appropriate stop plugs, as otherwise penetrating dirt and moisture damage components that are connected to the refrigerant circuit.

Installation: Replace seal rings on refrigerant lines (2).

4

Unclip condenser (1) from catch (4), swivel forwards at the left-hand side and remove

5

Remove filter dryer

Installation: Always replace the filter drier after opening the refrigerant circuit.

AR83.30-P-6525MCC

6

Install in the reverse order