ar8330p5430c

Removing and installing refrigerant pressure sensor

Tip ar · temă 83.30 · versiune 0102 · 2010-07-13

Valabil pentru: MODEL 129 as of 1.6.96 with CODE (581a) Air conditioning (automatic)

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 3 Suprastructură › 83 Climatizare › 83.30 Instalaţie de climatizare — Seria 129

EinPAS 39 Încălzire/Aerisire/Răcire › 39.15 Climatizare › 39.15.12 Senzor/Comutator/Cablaj — Seria 129

AR83.30-P-5430C

Removing and installing refrigerant pressure sensor

12.7.10

MODEL 129 as of 1.6.96 with CODE (581a) Air conditioning (automatic)

Removing and installing refrigerant pressure sensor

P83.30-0637-12

1 Fluid reservoir

2 Connector, refrigerant pressure sensor

B12 Refrigerant pressure sensor

Removal, installation

1

Empty air conditioning (recycle)

Installation: Evacuate air conditioning system, recharge, check for leakage and proper function by allowing engine to idle only for first 4 minutes.

2

Unhook and disconnect connector (2) on refrigerant pressure sensor (B12)

3

Remove refrigerant pressure sensor (B12) from fluid reservoir (1)

Plug opening on fluid reservoir
(part set no. 1408300127)

Installation: Replace sealing rings and moisten with compressor oil.

*BA83.30-P-1007-01A

4

Reinstall in opposite order

Air conditioning

Number

Designation

Model
129

BA83.30-P-1007-01A

Refrigerant pressure sensor on fluid reservoir

Nm

12