AR72.40-W-1000-03A | Set limit switch | ||
Danger! | Risk of injury from pinching and crushing when working on the folding door and the folding door control system | When working on the folding door or folding door control, relieve pressure from system with emergency lever (off position). |
W72.10-1008-11
The entrance lamp of the folding door in the entrance housing can be used to check the position of the limit switch.
1 Open folding door.
2 Close folding door until the adjustment point (A) is reached, keeping the entrance lamp in sight:
- Entrance lamp goes out too early continue adjustment procedure with step 3.
- Entrance lamp goes out too late or continues to illuminate ontinue adjustment procedure with step 3.
- Entrance lamp goes out immediately before adjustment point of folding door continue adjustment procedure with step 4.
10 B-pillar rubber channel
11 Folding door rubber channel
A Adjustment point (0...5 mm)
W72.40-1010-11
3 Loosen bolts on door open/closed limit switch (S129) and adjust door open/closed limit switch (S129) so that the entrance lamp just starts to illuminate.
As the folding door closes beyond the adjustment point the entrance lamp is supposed to go off.
4 Recheck adjustment of door open/closed limit switch (S129) by opening or closing the folding door repeatedly beyond the adjustment point.
The entrance lamp should go off a the adjustment point. If not repeat step 3.