ar5418t0002ca

Disconnecting and connecting electrical cables from battery

Tip ar · temă 54.18 · versiune 0101 · 2012-02-23

Valabil pentru: MODEL 613.368 with ENGINE 457.941

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 2 Sistem de rulare › 54 Instalaţie electrică, echipament şi instrumente › 54.18 Cablaje — Seria 613 (modele 368)

EinPAS 25 Rețea de bord/Rețea/Multi-funcție › 25.20 Reţea de bord › 25.20.12 Senzor/Comutator/Cablaj — Seria 613 (modele 368)

Valabil și pentru motoare/cutii de viteze: 457 941

AR54.18-T-0002CA

Disconnecting and connecting electrical cables from battery

16.2.12

MODEL 613.368 with ENGINE 457.941

Disconnecting and connecting electrical cables from battery

T54.10-0031-11

1 Battery isolating switch

2 Battery tray

Disconnecting

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

1

Switch off ignition

2

Open the maintenance flap on the left behind the rear axle

3

Position battery isolating switch (1) on "0"

4

Remove the locks on the battery tray (2) and pull out the battery tray (2)

5

Disconnect battery terminals

Avoid unintentional contact between the battery posts, risk of a short-circuit.

First negative terminal, then positive terminal.

Battery notes

All models

AH54.10-P-0001-01A

Inspect

6

Check all electrical contacts for damage

Replace parts or batteries if necessary.

Connecting

7

Connect battery terminals

First positive terminal, then negative terminal. Attach protective caps again if necessary

8

Push in batteries with battery tray (2) and lock

9

Position battery isolating switch (1) on "1"

10

Close maintenance flap

11

Set tachograph, clock and radio

See Operating Instructions

Documente menționate